Water hardness
Soft to moderately hard42–94mg/L as CaCO₃
≈ 2.4–5.5 grains per gallon
Reported utility hardness. A softener reduces the minerals that cause scale; a standard filter does not soften water.
2024 verified data; current report linked
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
42–94mg/L as CaCO₃
≈ 2.4–5.5 grains per gallon
Reported utility hardness. A softener reduces the minerals that cause scale; a standard filter does not soften water.
3.4ppm
Report comparison: 4 ppm disinfectant limit.
The displayed result is the report’s compliance average. Individual samples can be higher. Filtration can target disinfectant taste and odor.
Not detected
No amount above the reporting threshold in the listed monitoring.
Not detected does not mean zero. Reporting thresholds are not the same as regulatory limits or health goals.
0.23ppm
Report comparison: 4 ppm federal primary limit.
This is a historical sample, not a statement about current fluoridation. Fluoride reduction needs a dedicated treatment option.
60.4ppb
Reported compliance value.
Reported compliance values differ from individual sample peaks. Check the full table for ranges, dates and how each result was calculated.
29.5ppb
Reported compliance value.
Reported compliance values differ from individual sample peaks. Check the full table for ranges, dates and how each result was calculated.
1.2ppb
90th percentile across sampled taps.
A 90th-percentile result is not your tap result or the highest sample. Below an action level does not mean zero risk; lead’s health goal is zero.
0.0378ppm
90th percentile across sampled taps.
A utility percentile does not tell you the level at your own tap.
2024 verified hardness; current report linked
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
58–102mg/L as CaCO₃
≈ 3.4–6.0 grains per gallon
Reported utility hardness. A softener reduces the minerals that cause scale; a standard filter does not soften water.
Not available
An amount has not been summarized for this provider.
This does not mean zero or prove that the substance is absent. Check the provider’s full report for the relevant year.
Not available
An amount has not been summarized for this provider.
This does not mean zero or prove that the substance is absent. Check the provider’s full report for the relevant year.
Not available
An amount has not been summarized for this provider.
This does not mean zero or prove that the substance is absent. Check the provider’s full report for the relevant year.
Not available
An amount has not been summarized for this provider.
This does not mean zero or prove that the substance is absent. Check the provider’s full report for the relevant year.
Not available
An amount has not been summarized for this provider.
This does not mean zero or prove that the substance is absent. Check the provider’s full report for the relevant year.
Provider-specific results not selected
Continue with your home details for general filtration guidance. We will not use another utility’s numbers as your result.
Find My Water System →A utility report does not describe a private well
County utility results cannot tell us what is in your well. Use current laboratory results to choose treatment for your water and size the equipment for your home.
Find My Water System →Explore well-water systemsTHE DETAILS BEHIND THE HIGHLIGHTS
Explore the available local reports below. Each table names its supplier and dates; results from different providers are not interchangeable. The provider selector changes your highlights, while this section keeps the county’s source tables together.
The detailed results and hardness figures shown here come from verified 2024 utility reports, with older sample dates retained. The county and city both list 2025 reports; those newer numerical tables are not reproduced here. Open the current report for your supplier below.
ppm = mg/L; ppb = µg/L; ppt = ng/L. ND means below detection, not zero. MCL and MRDL are regulatory benchmarks reported in the source; action levels trigger system action. Annual averages, individual samples and household-tap percentiles are different measures. Compare like with like.
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Fluoride | 0.23 ppmReported detected level | MCL 4 ppm | 2023 Source |
| Nitrate (as nitrogen) | 0.11 ppmReported detected levelIndividual range: ND–0.11 ppm | MCL 10 ppm | 2024 Source |
| Sodium | 57.8 ppmReported detected levelIndividual range: 45.6–57.8 ppm | Source standard 160 ppm | 2023 Source |
| Barium | 0.0033 ppmReported detected levelIndividual range: ND–0.0033 ppm | MCL 2 ppm | 2023 Source |
| Chloramines | 3.4 ppmReported compliance averageIndividual range: 1.6–4.1 ppm | MRDL 4 ppm | 2024 Source |
| Haloacetic acids (HAA5) | 29.5 ppbReported compliance valueIndividual range: 17.7–34.6 ppb | MCL 60 ppb | 2024 Source |
| Total trihalomethanes (TTHM) | 60.4 ppbReported compliance valueIndividual range: 34.1–75.4 ppb | MCL 80 ppb | 2024 Source |
| Copper · household tapsNo sampled sites exceeded the action level. | 0.0378 ppm90th percentile · August–September | Action level 1.3 ppm | 2023 Source |
| Lead · household tapsNo sampled sites exceeded the action level. | 1.2 ppb90th percentile · August–September | Action level 15 ppb | 2023 Source |
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| PFOSND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
| PFOAND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
| PFHxSND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
| PFNAND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
| PFBSND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
| PFBAND does not mean zero; no exact concentration is assigned. | Not detectedOctober 2024 UCMR5 sample | See report for reporting limits | 2024 Source |
These results describe Collier County Regional Water Treatment Plant (FL5114069), not every home or water system in Collier County. Match this system to your water bill before using the results.
Source record: COLLIER COUNTY REGIONAL WTP · Selected test records: 2014-04-07 – 2025-04-23
Results come from different testing periods. A detection is not, by itself, a finding that water is unsafe. “Not detected” means below the test’s reporting level; it does not mean zero. Missing results mean we have not verified that data here.
MyTapWater reports no detections in this panel. Reporting limits vary by compound. The named compounds below are those individually verified in the retrieved source; the full panel is available through the source link. Selected PFAS sample dates: 2024-10-21 – 2025-04-23
MyTapWater reports lithium was tested and not detected. Sample dates and reporting limits: see the source report.
Selected historical tests, with their original dates. “Detected” means at least one positive result in the listed period. “Below reporting level” means all retrieved samples for that entry were below the reporting level. These older tests do not describe today’s water at your tap.
| Substance | Reported result | Sampling period |
|---|---|---|
| HAA5 | Detected | – |
| HAA6Br | Detected | – |
| HAA9 | Detected | – |
| chlorate | Detected | – |
| chromium | Detected | – |
| chromium-6 | Detected | – |
| strontium | Detected | – |
| vanadium | Detected | – |
| butylated hydroxyanisole | Below reporting level | – |
| germanium | Below reporting level | – |
| o-toluidine | Below reporting level | – |
| quinoline | Below reporting level | – |
This is a selection of results from MyTapWater, which compiles public water-system records. Open the source for the complete tables, methods and reporting limits. Check your utility’s latest report and current notices for updates. Source
A list of tested substances is not a list of what a filter removes. Choose a system using its verified contaminant-reduction specifications and your water source. A softener addresses hardness. Use the published hardness for your provider or a home test to choose softening for scale control.
No. Check the utility name on your bill. The county utility and City of Naples have different reports; other providers and private wells need their own water information. Source
Regional groundwater and delivered drinking water are different measurements. Collier’s report describes membrane treatment and lime softening. Use the dated finished-water figure for your supplier, then test at home before deciding on a softener. Source
No. Utility reports describe particular systems and sample periods. Plumbing, service lines and treatment already in a home can change the result at the tap.
No. Select equipment by its specific tested or certified reduction claims and rated flow. A long contaminant list is not evidence that a particular system removes every item.
No result rows match that search. Try another substance or clear your search.
Next, match the equipment to your home and water source.
These labels compare a reported result with its stated benchmark. They are not a blanket safety rating. Health goals, compliance limits, action levels and reporting thresholds mean different things.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
For Naples, start with the named provider and source dates above. Where a separate city dataset is not available, this guide uses Collier County reference records. Those records describe the listed utility, not every home in the city.
This Naples guide uses the named utility records from our county reports. The provider name, dates and source on each result show which system it describes. City boundaries alone do not identify your supplier.
City of Naples · local utility source ↗USGS classifies 0–60 mg/L as soft, 61–120 as moderately hard, 121–180 as hard and above 180 as very hard. These describe mineral content, not a health-based limit. A regional map cannot replace a home hardness test.
USGS hardness classifications and limitationsFiltration can address taste, odor, sediment and specific substances when the treatment is designed for them. A softener reduces calcium and magnesium. Your water source, actual hardness and household flow needs guide the combination.
Compare filters and softenersA county or utility report does not test your plumbing or private well. It also cannot prove that a particular filter removes every substance shown. Check the exact system’s treatment stages and verified claims for your goal.
What a whole-house filter can addressA city name, mailing address or ZIP code alone does not establish your water supplier. Municipal systems, county utilities and private wells can serve different addresses in the same area.
Bathroom count and simultaneous water use help size the filter. Your plumber checks the main water line, installation space and drain access. Condos and homes with shared plumbing may need building approval or a different installation.
For a private well, use a current well-water test to choose treatment. Public utility reports do not measure your well.
FROM REPORT TO BETTER WATER
Use the local report as a starting point, then choose the right system size and treatment options.
Match the supplier on your bill. For a private well, use current test results.
Tell us the home details needed for sizing and whether you want dedicated fluoride treatment.
Hire and pay a licensed plumber to confirm the installation layout, water pressure and space requirements.
Water reports, hardness guidance and a starting point for your home.
View water report →Water reports, hardness guidance and a starting point for your home.
View water report →A useful local question
This guide uses the named utility records from our county reports, with local utility links where available. The supplier, sampling period and source stay attached to each result. Confirm the provider on your bill before applying a result to your home.
Check the water-hardness highlight for the selected provider. It distinguishes a utility result, a regional estimate and unavailable data. A regional estimate is not a measurement of treated water at your tap. Test your incoming water to confirm hardness for system sizing.
A softener is recommended for scale control when the reported or measured hardness supports it. The recommendation beside the highlights explains that distinction. Unknown hardness is not zero; test it before selecting and programming a softener.
Start with a whole-house filter sized for your bathrooms and simultaneous water use. Match its treatment media and verified model-specific reduction claims to your goals. A softener reduces hardness minerals. You choose, hire and pay your own licensed plumber for installation.
No. Answer the home-sizing questions to get started. Your licensed plumber confirms the installation fit. A street address is not required in the matching form.
Each highlight links to its source. Open the full report for the longer tables, sampling details and additional source documents. A date on one result does not update every other result on the page.
Utility measurements take priority over regional estimates when they are available for that provider. Source dates are preserved. Hardness is converted using mg/L as CaCO₃ ÷ 17.1; regional estimates are not presented as home measurements.
Your water → your home → your system
Choose the system size, keep useful existing equipment, and review your filtration goals.