Hardness
Very hard363 / 386ppm
Superior Street / Philips Street levels
Combined sample range: 240–520 ppm, about 14.0–30.4 gpg.
2025 report; individual sample dates shown
For Indiana American Water’s Kokomo system (IN5234007). Keep the two plant results separate when reviewing water for a Howard County home.
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
363 / 386ppm
Superior Street / Philips Street levels
Combined sample range: 240–520 ppm, about 14.0–30.4 gpg.
1.44ppm
Highest running annual average
Chlorine is listed separately at 1.10 ppm RAA.
56.8ppb
Highest reported locational running annual average
Individual samples: 4.1–86.2 ppb. The 80 ppb limit is applied to the locational running annual average.
21.2ppb
Highest reported locational running annual average
0.54 / 0.57ppm
Superior Street / Philips Street results
2ppb
90th percentile at sampled taps
A utility percentile is not a test at your tap.
0.836ppm
90th percentile at sampled taps
A utility percentile is not a test at your tap.
3.37ppm
Superior Street result; Philips Street ND
Continue with your home details for general filtration guidance. We will not use another utility’s numbers as your result.
Find My Water System →A city report cannot establish a well’s water quality. Well-water treatment depends on your test results and site conditions.
Explore well-water systems →The figures below are provider-specific. They are not a countywide average.
| Utility | Hardness | Hardness source |
|---|---|---|
| 363 / 386 ppm plant levels · very hard | 2025 |
Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.
Open the complete utility report ↗
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 363 / 386 ppmSuperior Street / Philips Street levels | 2025View source ↗ | Very hardCombined sample range: 240–520 ppm, about 14.0–30.4 gpg. |
| Chloramines | 1.44 ppmHighest running annual average | 2025View source ↗ | Below 4 ppm MRDLChlorine is listed separately at 1.10 ppm RAA. |
| TTHMs | 56.8 ppbHighest reported locational running annual average | 2025View source ↗ | Below 80 ppb MCLIndividual samples: 4.1–86.2 ppb. The 80 ppb limit is applied to the locational running annual average. |
| HAA5 | 21.2 ppbHighest reported locational running annual average | 2025View source ↗ | Below 60 ppb MCL |
| Fluoride | 0.54 / 0.57 ppmSuperior Street / Philips Street results | 2025View source ↗ | Below 4 ppm MCL |
| Lead | 2 ppb90th percentile at sampled taps | 2024View source ↗ | Below the report’s 15 ppb action levelA utility percentile is not a test at your tap. |
| Copper | 0.836 ppm90th percentile at sampled taps | 2024View source ↗ | Below the report’s 1.3 ppm action levelA utility percentile is not a test at your tap. |
| Nitrate | 3.37 ppmSuperior Street result; Philips Street ND | 2025View source ↗ | Below 10 ppm MCL |
| Chlorine | 1.10 ppmHighest running annual average | 2025View source ↗ | Below 4 ppm MRDLIndividual range: 0.38–1.84 ppm. |
In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.
MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.
PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation ↗
Choose the system size, keep useful existing equipment, and review your filtration goals.
Source water. Kokomo uses Wildcat Creek surface water and groundwater from 16 wells.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
Kokomo’s Superior Street and Philips Street plants have separate hardness and chemical values. Keeping both helps avoid treating a single plant number as a countywide measurement.
The reported TTHM sample range reaches 86.2 ppb, while the highest locational running annual average is 56.8 ppb. Those are different statistics; the report applies its 80 ppb benchmark to the rolling average.
A useful local question
The report lists 363 ppm at Superior Street and 386 ppm at Philips Street. The combined sample range is 240–520 ppm. Confirm your supply and test incoming water before choosing final softener settings.
We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.
Confirm the exact system on your water bill. Choose Other / not sure when your supplier is not summarized here.
Sources reviewed November 12, 2026. Individual sampling dates are shown with each result.