Water hardness
Moderately hard to hard120–140mg/L as CaCO₃
Utility’s typical treated-water range
USGS hardness classification
Del-Co removes some calcium and magnesium during treatment. Its customer guide gives approximately 7–8 grains per gallon.
2025 annual water report · sampling dates shown below
These results apply to customers of Del-Co Water Company.
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
120–140mg/L as CaCO₃
Utility’s typical treated-water range
USGS hardness classification
Del-Co removes some calcium and magnesium during treatment. Its customer guide gives approximately 7–8 grains per gallon.
79.95ppb
Utility compliance result
Report limit 80 ppb
The utility reports 79.95 ppb as its compliance result and 24.8–75.3 ppb as its sample range. Its table records no violation.
38.78ppb
Utility compliance result
Report limit 60 ppb
Reported sample range 10.1–45.0 ppb.
1.48ppm
Utility-reported disinfectant residual
Report disinfectant limit 4 ppm
Reported sample range 1.34–1.62 ppm.
0.85ppb
90th percentile at sampled taps
Action level in this report 15 ppb
None of 50 taps exceeded 15 ppb.
0.22ppm
90th percentile at sampled taps
Action level in this report 1.3 ppm
None of 50 taps exceeded 1.3 ppm.
Continue with your home details for general filtration guidance. We will not use another utility’s numbers as your result.
Find My Water SystemA city report cannot establish a well’s water quality. Well-water treatment depends on your test results and site conditions.
Explore well-water systemsThe figures below are provider-specific. They are not a countywide average.
| Utility | Hardness | Hardness source |
|---|---|---|
| 120–140 mg/L · utility’s typical treated-water range | Utility hardness guidance reviewed November 24, 2026 |
Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.
Open the complete utility report
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | 120–140 mg/L as CaCO₃Utility’s typical treated-water range | Utility hardness guidance reviewed November 24, 2026View source | Moderately hard to hardDel-Co removes some calcium and magnesium during treatment. Its customer guide gives approximately 7–8 grains per gallon. |
| TTHM | 79.95 ppbUtility compliance result | 2025View source | Below 80 ppbThe utility reports 79.95 ppb as its compliance result and 24.8–75.3 ppb as its sample range. Its table records no violation. |
| HAA5 | 38.78 ppbUtility compliance result | 2025View source | Below 60 ppbReported sample range 10.1–45.0 ppb. |
| Chlorine | 1.48 ppmUtility-reported disinfectant residual | 2025View source | Below 4 ppm MRDLReported sample range 1.34–1.62 ppm. |
| Lead | 0.85 ppb90th percentile at sampled taps | 2024View source | Below 15 ppbNone of 50 taps exceeded 15 ppb. |
| Copper | 0.22 ppm90th percentile at sampled taps | 2024View source | Below 1.3 ppmNone of 50 taps exceeded 1.3 ppm. |
| Fluoride | 1.08 ppmReported treatment result | 2025View source | Below 4 ppm MCLReported range 0.86–1.18 ppm. |
In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.
MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.
PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation
Choose the system size, keep useful existing equipment, and review your filtration goals.
Source water. Del-Co draws surface water from the Olentangy River, O’Shaughnessy Reservoir and Alum Creek Reservoir. A fourth plant uses groundwater.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
Del-Co and the City of Delaware issue separate reports. If Del-Co is on your bill, its hardness guidance and tap sampling apply. City of Delaware customers can find their own utility report in the sources below.
A useful local question
Match the utility on your bill to Del-Co Water Company. If your supplier is different, use its annual report. For a private well, use a current test from your own well.
We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.
Confirm the exact system on your water bill. Choose Other / not sure when your supplier is not summarized here.
Sources reviewed November 24, 2026. Individual sampling dates are shown with each result.
Your water → your home → your system
Choose the system size, keep useful existing equipment, and review your filtration goals.