Hardness
Test neededNot reported
No numeric hardness in the reviewed report. Test incoming water before softener sizing.
2025 annual report; individual sample dates shown
Morenci Water & Electric — Morenci. Match the system name on your water bill.
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
Not reported
No numeric hardness in the reviewed report. Test incoming water before softener sizing.
39.63µg/L
Running annual average; individual samples 15–91
80 µg/L MCL
The report uses an annual average; an individual sample is not the compliance result.
20.74µg/L
Running annual average; sample range 8.7–58
60 µg/L MCL
0.58mg/L
Reported result
4 mg/L MCL
0.68µg/L
No samples exceeded the listed action level
15 µg/L action level
1.6µg/L
Reported result
10 µg/L MCL
2025 annual report; individual sample dates shown
Morenci Water & Electric — Clifton. Match the system name on your water bill.
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
Not reported
No numeric hardness in the reviewed report. Test incoming water before softener sizing.
1.39mg/L
Running annual average; sample range 0.2–1.39
4 mg/L MRDL
75µg/L
Highest result; range 0–75
80 µg/L MCL
28µg/L
Highest result; range 16–28
60 µg/L MCL
0.061mg/L
Reported result
10 mg/L MCL
0.56mg/L
Reported result
4 mg/L MCL
Continue with your home details for general filtration guidance. We will not use another utility’s numbers as your result.
Find My Water System →A city report cannot establish a well’s water quality. Well-water treatment depends on your test results and site conditions.
Explore well-water systems →The figures below are provider-specific. They are not a countywide average.
| Utility | Hardness | Hardness source |
|---|---|---|
| Not reported — test needed | 2025 annual report | |
| Not reported — test needed | 2025 annual report |
Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.
Open the complete utility report ↗
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not reported No numeric hardness in the reviewed report. Test incoming water before softener sizing. | 2025 annual reportView source ↗ | Test needed |
| Total trihalomethanes | 39.63 µg/LRunning annual average; individual samples 15–91 | 2025View source ↗ | Annual average below listed limitThe report uses an annual average; an individual sample is not the compliance result. |
| Haloacetic acids (HAA5) | 20.74 µg/LRunning annual average; sample range 8.7–58 | 2025View source ↗ | Below listed limit60 µg/L MCL |
| Fluoride | 0.58 mg/LReported result | January 2021View source ↗ | Below listed limit4 mg/L MCL |
| Lead (90th percentile) | 0.68 µg/LNo samples exceeded the listed action level | 2024View source ↗ | Below listed limit15 µg/L action level |
| Arsenic | 1.6 µg/LReported result | January 2021View source ↗ | Below listed limit10 µg/L MCL |
| Copper (90th percentile) | 0.1 mg/LNo samples exceeded the listed action level | 2024View source ↗ | Below listed limit1.3 mg/L action level |
| Disinfectant residual | See report The listed annual average and sample range do not align | 2025 reportView source ↗ | Utility clarification neededNo single disinfectant concentration is assigned in this guide. |
In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.
MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.
PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation ↗
Choose the system size, keep useful existing equipment, and review your filtration goals.
Source water. Surface water from Eagle Creek.
Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.
Open the complete utility report ↗
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not reported No numeric hardness in the reviewed report. Test incoming water before softener sizing. | 2025 annual reportView source ↗ | Test needed |
| Chlorine | 1.39 mg/LRunning annual average; sample range 0.2–1.39 | 2025View source ↗ | Below listed limit4 mg/L MRDL |
| Total trihalomethanes | 75 µg/LHighest result; range 0–75 | 2025View source ↗ | Below listed limit80 µg/L MCL |
| Haloacetic acids (HAA5) | 28 µg/LHighest result; range 16–28 | 2025View source ↗ | Below listed limit60 µg/L MCL |
| Nitrate (as nitrogen) | 0.061 mg/LReported result | 2025View source ↗ | Below listed limit10 mg/L MCL |
| Fluoride | 0.56 mg/LReported result | 2025View source ↗ | Below listed limit4 mg/L MCL |
| Lead (90th percentile) | 1.4 µg/LNo samples exceeded the listed action level | August 2024View source ↗ | Below listed limit15 µg/L action level |
| Copper (90th percentile) | 0.019 mg/LNo samples exceeded the listed action level | August 2024View source ↗ | Below listed limit1.3 mg/L action level |
In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.
MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.
PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation ↗
Choose the system size, keep useful existing equipment, and review your filtration goals.
Source water. Clifton is a separate MWE water system from Morenci; use the Clifton report for this service.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
Choose Morenci or Clifton to see the correct source results.
MWE publishes separate reports for Morenci and Clifton. Morenci uses Eagle Creek surface water, and its results must not be assigned to Clifton, Duncan, other Greenlee County systems or private wells. Compare averages with averages and keep older sample years visible.
A useful local question
They are separate water systems with separate reports and sampling. Select the system on your bill. Morenci’s trihalomethane annual average and individual sample range are different statistics; use the report’s compliance basis when comparing them.
We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.
The systems covered here publish separate reports. Use the official links to confirm your utility and system. If yours is not listed, choose Other / not sure.
Sources reviewed November 14, 2026. Individual sample years are shown with each result.
Your water → your home → your system
Choose the system size, keep useful existing equipment, and review your filtration goals.