| Water hardness | ≈120–180 mg/L as CaCO₃Approximate hardness by service area | 2025View source | Moderately hard to hardThe county gives about 7 grains per gallon for Stonelick and Batavia townships and eastern Goshen Township. The rest of its service area averages about 10.5 grains per gallon. The mg/L figures are rounded conversions. |
| TTHM | 73.32 ppbUtility compliance result | 2025View source | Below 80 ppbReported sample range 11.6–113 ppb. |
| HAA5 | 27.76 ppbUtility compliance result | 2025View source | Below 60 ppbReported sample range 2.8–40.8 ppb. |
| Total chlorine | 1.2 ppmUtility-reported disinfectant residual | 2025View source | Below 4 ppm MRDLReported sample range 1.04–1.34 ppm. |
| Lead | 2.1 ppb90th percentile at sampled taps | 2023 · county systemView source | Below 15 ppbNone of 52 taps exceeded 15 ppb. |
| Copper | 0.595 ppm90th percentile at sampled taps | 2023 · county systemView source | 1 tap above action levelOne of 52 taps measured 1.51 ppm, above the 1.3 ppm action level. |
| Lead | 0.6 ppb90th percentile at sampled taps | 2023 · former Batavia Village systemView source | Below 15 ppbNone of 10 taps exceeded 15 ppb. |
| Copper | 0.101 ppm90th percentile at sampled taps | 2023 · former Batavia Village systemView source | Below 1.3 ppmNone of 10 taps exceeded 1.3 ppm. |
| PFOS | 10.9 pptMGS plant, finished water | December 3, 2025View source | Detected in this sampleThe same plant measured 9.22 ppt on May 28, 2025. |
| PFOS | 3.41 pptPUB plant, finished water | December 3, 2025View source | Detected in this sampleThe same plant measured 1.82 ppt on May 28, 2025. |
| PFOA | 3.75 pptPUB plant, finished water | December 3, 2025View source | Detected in this sampleThe May 28 sample measured 4.13 ppt at this plant. |
| Fluoride | 0.99 ppmReported treatment result | 2025View source | Below 4 ppm MCLReported range 0.10–1.3 ppm. |