Free U.S. shipping on every product · No minimum
Engineered & assembled in the USAStraightforward licensed-plumber installationCrystal Quest · Since 1994
  1. 1Your water
  2. 2Your home
  3. 3Your system

Elkhart County, Indiana Water Quality Report

Find My Water System
Showing utility report

Elkhart Public Works and Utilities

2025 report; individual sample dates shown

For Elkhart Public Works and Utilities (IN5220008). Goshen and other county suppliers need their own reports.

Your water at a glance

See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.

Hardness

Test needed

Not reported

No numeric result for this system

Test incoming hardness before softener sizing; the reviewed report does not list a numeric hardness result.

Chlorine

Below 4 ppm MRDL

1ppm

Highest running annual average

TTHMs

Below 80 ppb MCL

41ppb

Highest reported locational running annual average

2024–2025View source

HAA5

Below 60 ppb MCL

16ppb

Highest reported locational running annual average

2024–2025View source

Lead

Below the report’s 15 ppb action level

2ppb

90th percentile at sampled taps

A utility percentile is not a test at your tap.

Fluoride

Below 4 ppm MCL

0.94ppm

Highest result

March 5, 2024View source

PFOA

Below report’s 4 ppt benchmark

2.4ppt

Highest running annual average

Single-sample maximum: 5.1 ppt on August 6, 2025. This is a dated report comparison.

PFHxS

Below report’s 10 ppt benchmark

8.1ppt

Highest running annual average

Single-sample maximum: 11 ppt on December 16, 2025. Read the original PFAS table.

Water hardness by provider

The figures below are provider-specific. They are not a countywide average.

UtilityHardnessHardness source
Not reported · test needed2025
View Full Water ReportOpen the measured results, dates, comparisons and original utility report.

The numbers behind your report

Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.

Open the complete utility report ↗

What was measuredReported amountSample year / source dateHow to read it
HardnessNot reported No numeric result for this system2025View source ↗Test neededTest incoming hardness before softener sizing; the reviewed report does not list a numeric hardness result.
Chlorine1 ppmHighest running annual average2025View source ↗Below 4 ppm MRDL
TTHMs41 ppbHighest reported locational running annual average2024–2025View source ↗Below 80 ppb MCL
HAA516 ppbHighest reported locational running annual average2024–2025View source ↗Below 60 ppb MCL
Lead2 ppb90th percentile at sampled taps2025View source ↗Below the report’s 15 ppb action levelA utility percentile is not a test at your tap.
Fluoride0.94 ppmHighest resultMarch 5, 2024View source ↗Below 4 ppm MCL
PFOA2.4 pptHighest running annual average2025View source ↗Below report’s 4 ppt benchmarkSingle-sample maximum: 5.1 ppt on August 6, 2025. This is a dated report comparison.
PFHxS8.1 pptHighest running annual average2025View source ↗Below report’s 10 ppt benchmarkSingle-sample maximum: 11 ppt on December 16, 2025. Read the original PFAS table.
Copper0.356 ppm90th percentile at sampled taps2025View source ↗Below the report’s 1.3 ppm action levelA utility percentile is not a test at your tap.
Nitrate1.5 ppmHighest resultJanuary 2, 2025View source ↗Below 10 ppm MCL

In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.

MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.

PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation ↗

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →

Next: match my home →

Source water. Groundwater is pumped from the Northwest, North Main and South wellfields, then treated for the Elkhart municipal system.

Email this report

Email delivery is coming soon. Copy the report link to share it now.

More about your local water

What this means for your home

Whole-home filtration should be selected for documented reduction goals. A softener is for hardness minerals; it is not a substitute for verified PFAS reduction. The reviewed report does not provide numeric hardness for sizing.

No. The report gives individual sample maxima and running annual averages. Those statistics describe the sampled system and period. Use current supplier information and a suitable home test when you need an address-specific answer.

A useful local question

Can one Elkhart PFAS number describe every home?

No. The report gives individual sample maxima and running annual averages. Those statistics describe the sampled system and period. Use current supplier information and a suitable home test when you need an address-specific answer.

Sources and methodology

We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.

Official utility reports

Confirm the exact system on your water bill. Choose Other / not sure when your supplier is not summarized here.

Sources reviewed November 10, 2026. Individual sampling dates are shown with each result.

Your water → your home → your system

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →