Free U.S. shipping on every product · No minimum
Engineered & assembled in the USAStraightforward licensed-plumber installationCrystal Quest · Since 1994
  1. 1Your water
  2. 2Your home
  3. 3Your system

Your local water, explained

Fresno County Water Quality Report

City of Fresno results are a starting point, not one report for every county water system.

The City of Fresno’s 2025 report shows an average hardness of 129 mg/L, in the hard category. For homes on that supply, filtration plus softening is a sensible starting recommendation for chlorine and scale goals. Other county utilities and private wells need their own data.

Find My Water System →

Your water → your home → your system

Your water

Match the name on your water bill.

Check the supplier on your water bill. City and county boundaries can include several water systems.

Only the listed water system is summarized here. Choose “Other / not sure” if your bill shows a different supplier.

These are utility measurements, not a test at your tap or a current service advisory. Sources checked October 27, 2026

Choose the right utility report

The figures below are provider-specific. They are not a countywide average.

UtilityHardnessHardness source
129 mg/L as CaCO₃ · Hard average2025 · average; range 87–150
Showing utility report

City of Fresno Water Division

2025 utility report; measurement years are shown with each result

Use these results only if City of Fresno Water Division supplies your home. County and ZIP boundaries do not confirm a water provider.

Your water at a glance

See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.

Hardness

Hard average

129mg/L as CaCO₃

average; range 87–150

USGS hardness classes

About 7.5 gpg. The reported range includes moderately hard and hard water; confirm your home’s current level.

2025

View source ↗

Chlorine

Below the 4 mg/L limit

1.45mg/L

average; range 0.02–1.85

MRDL: 4 mg/L

Listed as chlorine (NaOCl) in the utility report. Select filtration for the disinfectant and desired flow.

2025

View source ↗

TTHMs

Reported value below 80 ppb

0.18µg/L (ppb)

reported average; range ND–4.3

MCL: 80 ppb

This average is transcribed from the report; it is not a household measurement.

2025

View source ↗

HAA5

Reported value below 60 ppb

4.30µg/L (ppb)

reported average; range ND–9.7

MCL: 60 ppb

Disinfection byproducts; use the report’s averaging and sampling context.

2025

View source ↗

Fluoride

Below California’s 2 mg/L limit

0.12mg/L

average; range 0.10–0.13

California MCL: 2 mg/L

A low reported result is not zero; fluoride reduction requires dedicated treatment.

2025

View source ↗

Lead

Below the report’s action level

ND90th percentile

53 sampled homes

Report action level: 15 ppb

No samples exceeded 15 ppb. A current tap test is needed to assess your own plumbing.

August 2025

View source ↗

Arsenic

Below the 10 ppb limit

3.15µg/L (ppb)

average; range ND–5.1

MCL: 10 ppb

The report’s 0.004 ppb health goal is much lower than the legal limit. Below MCL does not mean zero.

2025

View source ↗

PFAS

Some source results above notification levels

Detectedsource-well monitoring

some affected wells removed from service

Compound-specific results

PFOA, PFOS and PFHxS were detected. Use the detailed utility results and current supply information before selecting treatment.

2025

View source ↗
View Full Water ReportOpen the measured results, dates, comparisons and original utility report.

The numbers behind your report

Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.

Open the complete utility report ↗

What was measuredReported amountSample year / source dateHow to read it
Hardness129 mg/L as CaCO₃average; range 87–1502025View source ↗Hard averageAbout 7.5 gpg. The reported range includes moderately hard and hard water; confirm your home’s current level.
Chlorine1.45 mg/Laverage; range 0.02–1.852025View source ↗Below the 4 mg/L limitListed as chlorine (NaOCl) in the utility report. Select filtration for the disinfectant and desired flow.
TTHMs0.18 µg/L (ppb)reported average; range ND–4.32025View source ↗Reported value below 80 ppbThis average is transcribed from the report; it is not a household measurement.
HAA54.30 µg/L (ppb)reported average; range ND–9.72025View source ↗Reported value below 60 ppbDisinfection byproducts; use the report’s averaging and sampling context.
Fluoride0.12 mg/Laverage; range 0.10–0.132025View source ↗Below California’s 2 mg/L limitA low reported result is not zero; fluoride reduction requires dedicated treatment.
LeadND 90th percentile53 sampled homesAugust 2025View source ↗Below the report’s action levelNo samples exceeded 15 ppb. A current tap test is needed to assess your own plumbing.
Arsenic3.15 µg/L (ppb)average; range ND–5.12025View source ↗Below the 10 ppb limitThe report’s 0.004 ppb health goal is much lower than the legal limit. Below MCL does not mean zero.
PFASDetected source-well monitoringsome affected wells removed from service2025View source ↗Some source results above notification levelsPFOA, PFOS and PFHxS were detected. Use the detailed utility results and current supply information before selecting treatment.
Nitrate as nitrogen4.80 mg/Laverage; reported range ND–122025View source ↗Average below 10; high sample investigatedThe utility attributes the high Well 85 result to lab error after confirmation testing. Do not present 12 mg/L as a confirmed citywide level.
Chromium-62.50 µg/Laverage; range 0.1–9.62025View source ↗Below the 10 µg/L limitThe report’s 0.02 µg/L health goal is different from the MCL.
Copper0.18 mg/L90th percentileAugust 2025View source ↗Below the 1.3 mg/L action levelNo sampled homes exceeded the action level.
Tetrachloroethylene (PCE)0.07 µg/Laverage; range ND–1.92025View source ↗Below the 5 µg/L limitTreatment claims must name the exact contaminant and model.
Trichloroethylene (TCE)0.32 µg/Laverage; range ND–2.32025View source ↗Below the 5 µg/L limitA system average cannot identify the value at a particular home.
PFOA1.33 ng/L (ppt)average; source range ND–132025View source ↗Some samples above the report’s 4 ppt notification levelThe report describes affected wells removed from service. Notification levels are not MCLs.
PFOS1.58 ng/L (ppt)average; source range ND–242025View source ↗Some samples above the report’s 4 ppt notification levelThese source-well maxima do not establish a tap concentration.
PFHxS0.91 ng/L (ppt)average; source range ND–382025View source ↗Some samples above the report’s 3 ppt notification levelThe report includes well shutdowns; confirm current supply and compound-specific treatment.
PFBS0.46 ng/L (ppt)average; source range ND–72025View source ↗Below the report’s 500 ppt notification levelNotification levels and federal MCLs are different types of benchmarks.
Total dissolved solids186.8 mg/Laverage; range 87–2602025View source ↗Below report’s 1,000 mg/L secondary limitTDS does not establish whether a specific contaminant is present.

In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.

MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A PHG is a health goal, not the legal limit. Lead/copper action levels use system sampling percentiles, not a safe-tap threshold. TTHM/HAA5 comparisons use locational running annual averages.

PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. Notification and response levels in a utility report are not maximum contaminant levels; do not infer a compliance violation from a single value. EPA PFAS benchmarks and implementation ↗

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →

Next: match my home →

Source water. Groundwater wells and treated surface water associated with the Kings and San Joaquin rivers. Supply blends vary across the city.

Email this report

Email delivery is coming soon. Copy the report link to share it now.

More about your local water

What this means for your home

Fresno County contains many separate water systems. This guide’s numerical results are from the City of Fresno; they should not be assigned to Clovis, another city or a private well. The original report also documents source-well investigations and shutdowns, which must stay attached to the contaminant figures. For a well, arrange current laboratory testing before selecting treatment.

Related city reports

Different name on your water bill?

These local providers publish separate reports. Follow the matching utility link; the measurements above do not describe these systems.

A useful local question

Should every Fresno County home use the same water treatment?

No. City of Fresno’s hard-water average supports recommending a softener for customers with scale concerns, paired with appropriate filtration. A home on another utility or a well may have different hardness, nitrate or other treatment needs. Confirm the supplier and use source-specific results before sizing or ordering.

Sources and methodology

We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.

Sources checked October 27, 2026

Your water → your home → your system

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →