Hardness
Measurement neededNot reported
The reviewed utility report does not give a hardness measurement. Test incoming water to size a softener.
2025 water quality results
Highlights use the B.T. Brown plant column in CCWSA’s report. They are not an average across purchased supplies and do not represent Newnan Utilities retail customers.
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
Not reported
The reviewed utility report does not give a hardness measurement. Test incoming water to size a softener.
2.31mg/L
B.T. Brown plant column; range 1.33–2.31.
0.95mg/L
B.T. Brown plant column; range 0.24–0.95.
71.95µg/L
B.T. Brown plant reported level; range 11.3–71.95. Other supply columns have different results.
The report lists an 80 µg/L limit. Compliance uses running annual averages, not a single sample.
48.81µg/L
B.T. Brown plant reported level; range 9.98–48.81.
The report lists a 60 µg/L limit; use the stated reporting basis.
0.36mg/L
B.T. Brown plant column; range 0–0.36.
Continue with your home details for general filtration guidance. We will not use another utility’s numbers as your result.
Find My Water System →A city report cannot establish a well’s water quality. Well-water treatment depends on your test results and site conditions.
Explore well-water systems →The figures below are provider-specific. They are not a countywide average.
| Utility | Hardness | Hardness source |
|---|---|---|
| Not published in the reviewed report | No numeric hardness result in the reviewed report |
Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.
Open the complete utility report ↗
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not reported The reviewed utility report does not give a hardness measurement. Test incoming water to size a softener. | Reviewed report; no hardness valueView source ↗ | Measurement needed |
| Chlorine | 2.31 mg/LB.T. Brown plant column; range 1.33–2.31. | 2025View source ↗ | Below 4 mg/L disinfectant limit |
| Fluoride | 0.95 mg/LB.T. Brown plant column; range 0.24–0.95. | 2025View source ↗ | Below 4 mg/L limit |
| Total trihalomethanes (TTHM) | 71.95 µg/LB.T. Brown plant reported level; range 11.3–71.95. Other supply columns have different results. | 2025View source ↗ | Utility reports standard metThe report lists an 80 µg/L limit. Compliance uses running annual averages, not a single sample. |
| Haloacetic acids (HAA5) | 48.81 µg/LB.T. Brown plant reported level; range 9.98–48.81. | 2025View source ↗ | Utility reports standard metThe report lists a 60 µg/L limit; use the stated reporting basis. |
| Chlorine dioxide | 0.36 mg/LB.T. Brown plant column; range 0–0.36. | 2025View source ↗ | Below 0.8 mg/L disinfectant limit |
In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.
MCL means a regulatory contaminant limit; MRDL is a disinfectant limit. Lead and copper use tap-sampling action levels. TTHM and HAA5 compliance is assessed using running averages at specific locations, not the highest single sample.
PFAS results depend on the compound, sample location, year and reporting limit. A missing result or nondetect is not proof of zero PFAS. EPA PFAS benchmarks and implementation ↗
Choose the system size, keep useful existing equipment, and review your filtration goals.
Source water. CCWSA lists the B.T. Brown plant, Shoal Creek wells and purchased supplies from Newnan Utilities, Griffin and Atlanta.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
Review CCWSA’s B.T. Brown plant results alongside an explanation of its multiple water supplies.
Highlights use the B.T. Brown plant column in CCWSA’s report. They are not an average across purchased supplies and do not represent Newnan Utilities retail customers.
A useful local question
No. The highlights use the CCWSA report’s B.T. Brown plant column. CCWSA also purchases water from other suppliers, but a Newnan Utilities retail customer should use Newnan’s own report.
Results retain the utility, sample year, units and comparison used in the source. Hardness is shown separately as a utility measurement, utility guidance or regional estimate. USGS categories describe mineral content, not drinking-water safety.
Use the published report for your own retail water system. These sources can help identify the right report; a county or ZIP alone cannot confirm service.
Sources reviewed November 7, 2026.
Your water → your home → your system
Choose the system size, keep useful existing equipment, and review your filtration goals.