Free U.S. shipping on every product · No minimum
Engineered & assembled in the USAStraightforward licensed-plumber installationCrystal Quest · Since 1994
  1. 1Your water
  2. 2Your home
  3. 3Your system

Bartholomew County, Indiana Water Quality Report

Find My Water System
Showing utility report

Columbus City Utilities

June 2026 report covering 2025; older samples identified

For Columbus City Utilities (IN5203002). These measurements apply to the named utility, not all of Bartholomew County.

Your water at a glance

See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.

Hardness

Very hard

335ppm

2025 annual average; 19.6 gpg

Range: 328–344 ppm, or 19.2–20.1 gpg.

Chlorine

Below 4 ppm MRDL

1.3ppm

Highest running annual average

Individual range: 0.5–1.7 ppm.

TTHMs

Below 80 ppb MCL

22.8ppb

Highest reported locational running annual average

HAA5

Below 60 ppb MCL

7.8ppb

Highest reported locational running annual average

Fluoride

Below 4 ppm MCL

0.754ppm

Highest reported result

May 25, 2023View source

Lead

Below the report’s 15 ppb action level

1.7ppb

90th percentile at sampled taps

A utility percentile is not a test at your tap.

Copper

Below the report’s 1.3 ppm action level

0.3ppm

90th percentile at sampled taps

A utility percentile is not a test at your tap.

Nitrate

Below 10 ppm MCL

5.07ppm

Highest reported result, as nitrogen

Water hardness by provider

The figures below are provider-specific. They are not a countywide average.

UtilityHardnessHardness source
335 ppm annual average · very hard2025
View Full Water ReportOpen the measured results, dates, comparisons and original utility report.

The numbers behind your report

Selected results with the original sampling dates and measurement basis. Open the utility report for every parameter, notice and footnote.

Open the complete utility report ↗

What was measuredReported amountSample year / source dateHow to read it
Hardness335 ppm2025 annual average; 19.6 gpg2025View source ↗Very hardRange: 328–344 ppm, or 19.2–20.1 gpg.
Chlorine1.3 ppmHighest running annual average2025View source ↗Below 4 ppm MRDLIndividual range: 0.5–1.7 ppm.
TTHMs22.8 ppbHighest reported locational running annual average2025View source ↗Below 80 ppb MCL
HAA57.8 ppbHighest reported locational running annual average2025View source ↗Below 60 ppb MCL
Fluoride0.754 ppmHighest reported resultMay 25, 2023View source ↗Below 4 ppm MCL
Lead1.7 ppb90th percentile at sampled taps2023View source ↗Below the report’s 15 ppb action levelA utility percentile is not a test at your tap.
Copper0.3 ppm90th percentile at sampled taps2023View source ↗Below the report’s 1.3 ppm action levelA utility percentile is not a test at your tap.
Nitrate5.07 ppmHighest reported result, as nitrogen2025View source ↗Below 10 ppm MCL
PFBS9.6 pptHighest reported resultJanuary 14, 2025View source ↗Detection reportedConverted from 0.0096 ppb; no individual PFBS limit is listed.
PFBA9.2 pptHighest reported resultJanuary 14, 2025View source ↗Detection reportedConverted from 0.0092 ppb; no individual PFBA limit is listed.
PFHxA8.3 pptHighest reported resultJanuary 14, 2025View source ↗Detection reportedConverted from 0.0083 ppb; no individual PFHxA limit is listed.
PFPeA16.3 pptHighest reported resultJanuary 14, 2025View source ↗Detection reportedConverted from 0.0163 ppb; no individual PFPeA limit is listed.

In drinking water, ppm ≈ mg/L, ppb ≈ µg/L and ppt ≈ ng/L. Calculated hardness in grains per US gallon (gpg) = mg/L as CaCO₃ ÷ 17.118, rounded to one decimal. ND means below the reporting limit, not zero.

MCL is an enforceable contaminant limit; MRDL is a disinfectant limit. A secondary guideline concerns aesthetics. TTHM/HAA5 compliance uses locational running annual averages; read the utility’s notices as well as individual results.

PFAS results are compound-specific. Source monitoring, entry-point samples and tap tests are different. A detected result does not identify every PFAS compound or establish the level at your home. Read the original report for context and current utility notices. EPA PFAS benchmarks and implementation ↗

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →

Next: match my home →

Source water. Columbus obtains groundwater from 26 wells and uses two filtration plants.

Email this report

Email delivery is coming soon. Copy the report link to share it now.

More about your local water

What this means for your home

Columbus publishes a measured annual hardness average and range, making the difference between a typical value and sample variability visible. The supply comes from groundwater wells.

The full table includes PFBS, PFBA, PFHxA and PFPeA detections. Each is a distinct compound; a benchmark for one PFAS compound should not be applied to all of them.

A useful local question

Why are Columbus PFAS results shown in ppt?

The source table uses ppb. We convert those values to ppt by multiplying by 1,000 and identify the conversion in each row. No individual limit is invented for a compound without one in the report.

Sources and methodology

We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.

Official utility reports

Confirm the exact system on your water bill. Choose Other / not sure when your supplier is not summarized here.

Sources reviewed November 12, 2026. Individual sampling dates are shown with each result.

Your water → your home → your system

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →