Hardness
Hard · city guidance~180mg/L as CaCO₃
~10.5 gpg · hard water
Hard range: 121–180 mg/L. A softener is recommended to reduce scale.
Plant City’s figures do not represent every Hillsborough County water system. Check the utility name on your bill before using a report.
View Hillsborough County reports →A city report cannot tell you what is in your well. Use current well testing and a site-specific review to choose treatment.
Explore well-water systems →Find your utility’s report, or check with your property manager. We won’t apply Plant City’s numbers to an unknown supply.
Find my local report →2024 · samples from 2023–24
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
~180mg/L as CaCO₃
~10.5 gpg · hard water
Hard range: 121–180 mg/L. A softener is recommended to reduce scale.
1.58ppm
Report limit: 4.0 ppm
A filter can reduce chlorine taste and odor.
29 tested · all ND
In the listed utility samples
Below reporting levels. Not detected does not mean zero.
0.630ppm
Report limit: 4.0 ppm
Historical sample. Today’s fluoride level may differ.
74.025ppb
Highest locational annual average.
About 93% of the stated limit.
48.20ppb
Highest locational annual average.
About 80% of the stated limit.
1.0ppb
90th percentile across sampled taps.
Utility 90th percentiles. Your own tap may differ.
0.780ppm
90th percentile across sampled taps.
Utility 90th percentiles. Your own tap may differ.
Comparisons use the limits and action levels in the 2024 report. “Below” is not a safety guarantee; lead’s health goal is zero. Hardness describes mineral content and scale. Utility records are not a test at your tap.
LOOK BEHIND THE HIGHLIGHTS
These tables make selected utility records easier to read. Sample dates and comparison types matter: an annual average, a 90th percentile, and a single sample are different measurements. The city’s original documents contain the complete records.
Figures below use the 2024 utility report and 2024–25 monitoring. The city’s newer 2025 report is not represented. These are utility records, not a test at your tap. See current city reports ↗
All comparisons below are to benchmarks printed in that report. “Below” does not mean zero risk or confirm the result at your own tap.
| Substance | Reported result | Report benchmark | How it compares | Sample / reporting basis |
|---|---|---|---|---|
| Chlorine | 1.58 ppm | 4.0 ppm · MRDL | Below report limit | 2024 · highest running annual average |
| Total trihalomethanes (TTHM) | 74.025 ppb | 80 ppb · MCL | Below; 93% of limit | 2024 · highest locational running annual average |
| Haloacetic acids (HAA5) | 48.20 ppb | 60 ppb · MCL | Below; 80% of limit | 2024 · highest locational running annual average |
| Fluoride | 0.630 ppm | 4.0 ppm · MCL | Below report limit | March 2023 · highest reported result |
| Nitrate (as nitrogen) | 0.480 ppm | 10 ppm · MCL | Below report limit | February 2024 · highest reported result |
| Barium | 0.016 ppm | 2 ppm · MCL | Below report limit | March 2023 · highest reported result |
| Chromium | 12 ppb | 100 ppb · MCL | Below report limit | March 2023 · highest reported result |
| Lead | 1.0 ppb | 15 ppb · action level | Below action level | September 2023 · 90th percentile |
| Copper | 0.780 ppm | 1.3 ppm · action level | Below action level | September 2023 · 90th percentile |
| Alpha emitters | 3.00 pCi/L | 15 pCi/L · MCL | Below report limit | March 2023 · highest reported result |
| Combined radium | 1.70 pCi/L | 5 pCi/L · MCL | Below report limit | March 2023 · highest reported result |
TTHM’s 74.025 ppb and HAA5’s 48.20 ppb are the highest locational running annual averages. The TTHM single-sample range reached 88.80 ppb; that peak is not the averaging measure used for this comparison.
Open the original 2024 water quality report (PDF) ↗All 29 PFAS in the city’s listed 2024–25 monitoring samples were reported as not detected. That means below the method’s reporting level, not necessarily absent. The table below shows selected analytes whose reporting levels are clear in the source.
| Analyte | Listed sample result | Minimum reporting level |
|---|---|---|
| PFOS | Not detected | 0.0039 µg/L |
| PFHxS | Not detected | 0.0030 µg/L |
| PFBA | Not detected | 0.0050 µg/L |
| PFPeA | Not detected | 0.0030 µg/L |
| PFHxA | Not detected | 0.0030 µg/L |
| PFHpA | Not detected | 0.0030 µg/L |
| PFBS | Not detected | 0.0030 µg/L |
| Lithium (not a PFAS) | Not detected | 9.0 µg/L |
A minimum reporting level is a laboratory reporting threshold, not a drinking-water safety limit. See the full monitoring sheet for all 29 PFAS, sampling dates, and plant-level entries.
Open the complete 2024–25 monitoring sheet (PDF) ↗No matching substances in these selected tables. Try another name or open the original reports.
Your water points to the treatment. Your home determines the size.
Email delivery is coming soon. Copy the report link to share it now.
More about your local water
A report is a useful starting point. Here’s what these results can mean for a Plant City home—and what they cannot tell you.
The city gives approximate hardness guidance of 180 mg/L as CaCO₃, or 10.5 grains per gallon. That falls in the USGS “hard” range and supports recommending a softener for scale control.
Confirm hardness at your home when programming the softener. A utility estimate is not a substitute for that measurement.
City hardness guidance ↗USGS hardness scale ↗The city identifies chlorine treatment. The 2024 report’s highest running annual average was 1.58 ppm, below its 4.0 ppm report limit.
A suitable filter can reduce chlorine taste and odor. A softener addresses calcium and magnesium hardness; it does not take the filter’s place.
Filter vs. softener: understand the difference →Plumbing, service lines, sampling location, and time can affect results. A city report also does not apply to a private well or a different utility.
If lead, a specific contaminant, or a change in your water is your concern, use appropriate tap testing and check the exact treatment model’s verified reduction claim.
What a whole-house filter can—and can’t—do →YOUR NEXT STEP IS SIMPLE
Use the report to choose treatment, then match the system to your household’s needs.
Answer a few simple sizing questions.
See your recommendation and price before ordering.
You arrange and pay for installation separately.
A useful local question
City guidance puts hardness at approximately 180 mg/L as CaCO₃ (10.5 gpg). USGS classifies 121–180 mg/L as hard. This supports a softener recommendation for scale, with hardness at your home checked for final setup.
Hardness is high enough to fall in the hard-water category. The selected regulated results shown here are below their 2024 report benchmarks, although TTHM’s highest locational annual average is about 93% of its limit. Lead and copper use action levels, and PFAS “not detected” uses reporting thresholds. These are different kinds of comparison—not a single safety score.
No. These historical utility records describe the city system and sampled locations. They are not a current test of your household water. Check the city’s current report and use appropriate tap testing for home-specific questions.
The 0.630 ppm value is a March 2023 sample listed in the 2024 report. The city says it approved ending supplemental fluoride on March 24, 2025, so this older value should not be treated as today’s level. Standard whole-house filtration should not be assumed to remove fluoride; that requires appropriate, verified treatment.
Read the city’s fluoride guidance ↗No single generic claim covers every substance here. This recommendation addresses chlorine taste and odor plus hard-water scale. For lead, PFAS, fluoride, or another specific contaminant, check the exact model’s independently verified reduction claim and suitability for your measured water.
You choose, hire, and pay your own licensed plumber. Your plumber checks the service connection, space, drainage, electrical needs, and local requirements against the selected model’s installation manual.
View installation information →This report keeps utility records, laboratory reporting levels, and regulatory comparisons separate. The source documents control if a summary and original differ.
Report summary updated October 20, 2026 · Clearhouse
Your water → your home → your system
Choose the system size, keep useful existing equipment, and review your filtration goals.