Free U.S. shipping on every product · No minimum
Engineered & assembled in the USAStraightforward licensed-plumber installationCrystal Quest · Since 1994
  1. 1Your water
  2. 2Your home
  3. 3Your system

Your local water, explained

McKinney Water Quality Report

2025 city results, plus dated NTMWD hardness evidence.

McKinney's 2026 publication reports 2025 water data. Its city measurements stay separate from NTMWD supplier hardness ranges, which provide the starting evidence for a scale-control recommendation.

Find My Water System →

Your water → your home → your system

Your water

Match the name on your water bill.

The report follows your water provider—not your ZIP code or county boundary.

Only the listed water system is summarized here. Choose “Other / not sure” if your bill shows a different supplier.

Utility data is a starting point. It is not a test of your tap or a live advisory. Sources checked October 23, 2026

Showing utility report

City of McKinney

2025 city data with supplier values individually dated

Results for City of McKinney customers. Confirm the retail utility and system on your bill.

Your water at a glance

See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.

Hardness

Supplier range: moderate to very hard

Wylie: 96–200; Leonard: 96–144mg/L as CaCO₃

Ranges from NTMWD treatment plants; not city distribution or home measurements

The supplier ranges reach hard or very hard levels, supporting a softener recommendation for scale control; measure your incoming water to size and set it correctly.

2025

View source ↗

Chloramine

Below 4 ppm MRDL

2.22ppm

City average of quarterly data; individual samples0.2–3.8 ppm

The 0.2 ppm sample occurred during annual chlorine maintenance, when ammonia addition temporarily stops; ordinary treatment uses chloramine.

2025

View source ↗

TTHMs

Below 80 ppb comparison

35.4ppb

Highest locational running annual average

Below the report’s stated benchmark; this does not mean absent or describe an individual tap.

2025

View source ↗

HAA5

Below 60 ppb comparison

20.5ppb

Highest locational running annual average

Below the report’s stated benchmark; this does not mean absent or describe an individual tap.

2025

View source ↗

Fluoride

Below 4 ppm MCL comparison

Wylie 0.492; Leonard 0.225ppm

Highest detected NTMWD supplier results

These values are measured at supplying plants, not individual McKinney homes.

2025

View source ↗

Lead

Below 15 ppb action level

0.903ppb

90th-percentile tap sampling result; zero sites above the action level

This system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap.

2025

View source ↗

PFAS

Cannot assess high or low

Not verified

No compound-specific result assessed in this summary

This does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment.

2025 report review

View source ↗

Nitrate

Below 10 ppm comparison

0.397ppm

Highest city distribution result

Below the report’s stated benchmark; this does not mean absent or describe an individual tap.

2025

View source ↗
View Full Water ReportOpen the measured results, dates, comparisons and original utility report.

The numbers behind your report

Selected useful results—not a replacement for the utility’s complete report. Older measurements retain their original year.

Open the complete utility report ↗

What was measuredReported amountSample year / source dateHow to read it
Water hardnessWylie: 96–200; Leonard: 96–144 mg/L as CaCO₃Ranges from NTMWD treatment plants; not city distribution or home measurements2025View source ↗Moderately hard to very hard (Wylie); moderately hard to hard (Leonard)The supplier ranges reach hard or very hard levels, supporting a softener recommendation for scale control; measure your incoming water to size and set it correctly.
Chloramine2.22 ppmCity average of quarterly data; individual samples0.2–3.8 ppm2025View source ↗Below 4 ppm MRDLThe 0.2 ppm sample occurred during annual chlorine maintenance, when ammonia addition temporarily stops; ordinary treatment uses chloramine.
Total trihalomethanes (TTHM)35.4 ppbHighest locational running annual average2025View source ↗Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap.
Haloacetic acids (HAA5)20.5 ppbHighest locational running annual average2025View source ↗Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap.
FluorideWylie 0.492; Leonard 0.225 ppmHighest detected NTMWD supplier results2025View source ↗Below 4 ppm MCL comparisonThese values are measured at supplying plants, not individual McKinney homes.
Nitrate as nitrogen0.397 ppmHighest city distribution result2025View source ↗Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap.
Lead0.903 ppb90th-percentile tap sampling result; zero sites above the action level2025View source ↗Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap.
Copper0.787 ppm90th-percentile tap sampling result; zero sites above the action level2025View source ↗Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap.
PFASNot verified No compound-specific result assessed in this summary2025 report reviewView source ↗Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment.

ppm ≈ mg/L; ppb ≈ µg/L; ppt ≈ ng/L in drinking water. Hardness in gpg = mg/L as CaCO₃ ÷ 17.1. ND means not detected at the method’s reporting limit—not zero.

MCL is a maximum contaminant level. MRDL is a disinfectant limit. Lead/copper action levels use system sampling percentiles and are not a safe-tap threshold. TTHM/HAA5 compliance uses locational annual averages.

PFOA/PFOS comparisons use EPA’s 4 ppt values. Historical detections are not a present compliance finding; EPA assesses compliance using running annual averages. Rule implementation is being reviewed. EPA PFAS benchmarks and implementation ↗

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →

Next: match my home →

Source water. McKinney receives treated surface water from NTMWD. Its report includes Wylie and Leonard supplier results alongside tests collected within McKinney’s distribution system.

Email this report

Email delivery is coming soon. Copy the report link to share it now.

More about your local water

What this means for your home

McKinney receives NTMWD-treated surface water. The hardness ranges shown come from the supplier's 2025 plant table, because a citywide numerical hardness table is not supplied here. The report's inconsistent PFBA row is not turned into a numerical PFAS claim.

A useful local question

Does a report labelled 2026 contain only 2026 samples?

No. McKinney's 2026 drinking-water report summarizes 2025 data, with individual rows retaining their actual sampling dates. Publication year and measurement year are different.

Sources and methodology

We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.

Sources checked October 23, 2026

Your water → your home → your system

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →