Free U.S. shipping on every product · No minimum
Engineered & assembled in the USAStraightforward licensed-plumber installationCrystal Quest · Since 1994
  1. 1Your water
  2. 2Your home
  3. 3Your system

Your local water, explained

Kyle Water Quality Report

Very hard water, with naturally occurring fluoride.

Kyle's 2025 report lists hardness of 275–295 mg/L as calcium carbonate. We suggest filtration plus softening for homes seeking scale control; dedicated fluoride treatment is a separate configuration if that is your goal.

Find My Water System →

Your water → your home → your system

Your water

Match the name on your water bill.

The report follows your water provider—not your ZIP code or county boundary.

Only the listed water system is summarized here. Choose “Other / not sure” if your bill shows a different supplier.

Utility data is a starting point. It is not a test of your tap or a live advisory. Sources checked October 23, 2026

Showing utility report

City of Kyle

2025 report; each row keeps its measurement year

Results for City of Kyle customers on system TX1050002. Other districts and private wells need their own reports.

Your water at a glance

See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.

Hardness

Very hard

275–295 mg/L as CaCO₃

Reported hardness range, varies with groundwater use

USGS very hard: >180 mg/L

2025 report

View source ↗

Free chlorine

Below stated benchmark

1.43 ppm

City-system average; range 0.55–2.8

MRDL 4 ppm

2025

View source ↗

TTHMs

Below limit

67 ppb

Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; site's individual range 47.3–83.8

MCL 80 ppb, LRAA basis

2025

View source ↗

HAA5

Below limit

25 ppb

Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; range 14–48

MCL 60 ppb, LRAA basis

2025

View source ↗

Fluoride

Below primary limit

1.83 ppm

Highest reported City-system result

MCL 4 ppm

Naturally occurring; Kyle says it does not add fluoride.

January 8, 2025

View source ↗

Lead

Below action level

1.91 ppb

90th percentile; range 0–3.9; zero sites above action level

Report action level 15 ppb; MCLG0

2023–2025 monitoring period

View source ↗

PFAS

Cannot assess high or low

Not verified

No compound-specific result assessed in this summary

This does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment.

2025 report review

View source ↗

Nitrate

Below limit

1.83 ppm

Highest reported result; range 0–1.83

MCL 10 ppm

January 8, 2025

View source ↗
View Full Water ReportOpen the measured results, dates, comparisons and original utility report.

The numbers behind your report

Selected useful results—not a replacement for the utility’s complete report. Older measurements retain their original year.

Open the complete utility report ↗

What was measuredReported amountSample year / source dateHow to read it
Hardness275–295 mg/L as CaCO₃ Reported hardness range, varies with groundwater use2025 reportView source ↗Very hard · USGS very hard: >180 mg/L
Free chlorine1.43 ppm City-system average; range 0.55–2.82025View source ↗Below stated benchmark · MRDL 4 ppm
Total trihalomethanes (TTHM)67 ppb Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; site's individual range 47.3–83.82025View source ↗Below limit · MCL 80 ppb, LRAA basis
Haloacetic acids (HAA5)25 ppb Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; range 14–482025View source ↗Below limit · MCL 60 ppb, LRAA basis
Fluoride1.83 ppm Highest reported City-system resultJanuary 8, 2025View source ↗Below primary limit · MCL 4 ppmNaturally occurring; Kyle says it does not add fluoride.
Nitrate as nitrogen1.83 ppm Highest reported result; range 0–1.83January 8, 2025View source ↗Below limit · MCL 10 ppm
Lead1.91 ppb 90th percentile; range 0–3.9; zero sites above action level2023–2025 monitoring periodView source ↗Below action level · Report action level 15 ppb; MCLG0A system sampling percentile is not a measurement of your faucet.
Copper0.0975 ppm 90th percentile; range 0.00279–0.241; zero sites above action level2023–2025 monitoring periodView source ↗Below action level · Action level 1.3 ppmA system sampling percentile is not a measurement of your faucet.
PFASNot verified No compound-specific result assessed in this summary2025 report reviewView source ↗Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment.

ppm ≈ mg/L; ppb ≈ µg/L; ppt ≈ ng/L in drinking water. Hardness in gpg = mg/L as CaCO₃ ÷ 17.1. ND means not detected at the method’s reporting limit—not zero.

MCL is a maximum contaminant level. MRDL is a disinfectant limit. Lead/copper action levels use system sampling percentiles and are not a safe-tap threshold. TTHM/HAA5 compliance uses locational annual averages.

PFOA/PFOS comparisons use EPA’s 4 ppt values. Historical detections are not a present compliance finding; EPA assesses compliance using running annual averages. Rule implementation is being reviewed. EPA PFAS benchmarks and implementation ↗

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →

Next: match my home →

Source water. Purchased surface water and treated groundwater: local Edwards/Barton Springs wells, GBRA, City of San Marcos, and Alliance Regional Water Authority.

Email this report

Email delivery is coming soon. Copy the report link to share it now.

More about your local water

What this means for your home

Kyle's report distinguishes City-system results from purchased-water supplier data. Its own highest listed TTHM annual compliance value is 67 ppb; a different supplier's result should not be substituted. The City says it does not add fluoride.

A useful local question

Does Kyle add fluoride to its water?

The City says it does not. The 2025 City-system result of 1.83 ppm reflects naturally occurring fluoride and is below the reported 4 ppm primary limit. A standard filter and dedicated fluoride treatment serve different purposes.

Sources and methodology

We keep each utility’s results separate, show the reported sample year, and distinguish averages, maxima and tap-sampling percentiles. Hardness classifications use USGS ranges. Missing data stays unknown.

Sources checked October 23, 2026

Your water → your home → your system

Turn your report into a plan for your home.

Choose the system size, keep useful existing equipment, and review your filtration goals.

Find My Water System →