Your local water, made clear.
Match this to the name on your water bill.
Your water at a glance
See the amount, the comparison and what it means. “Below” refers to the stated benchmark, not zero risk.
Choose your water provider to see its measured results and comparisons.
Use the provider on your bill. Utility results are not a test of the water at your tap.
Next: Your home details. No email required.
Explore your report
View full water reportContaminants and measured results
Choose a listed utility to see its report, or continue with your home details.
Selected Manatee County Utilities results. Open the full report for minerals, PFAS monitoring, tests with no detection and the original source tables.
| Substance / measure | Reported result | Year / source |
|---|---|---|
| Chloramines | 3.3 ppmHighest running annual average | 2025 [1] |
| Total trihalomethanes (TTHM) | 47.1 ppbHighest locational annual average | 2025 [1] |
| Haloacetic acids (HAA5) | 39.5 ppbHighest locational annual average | 2025 [1] |
| Lead · sampled household taps | 1.1 ppb90th percentile · Jun–Sep 2025 | 2025 [1] |
| Chromium · total | 0.57 ppbHighest result | 2025 [1] |
| Cyanide | 31 ppbHighest result | 2025 [1] |
| Fluoride | 0.32 ppmHighest result | 2025 [1] |
| Atrazine | 0.03 ppbHighest result | 2025 [1] |
Measurements have different sampling bases. Detection does not automatically mean a violation, and these results are not a test of your home’s tap.
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine and chloraminesIndividual samples and annual compliance averages are different measures. | 3.6 ppmHighest running annual averageIndividual range: 0.4–5.3 ppm | MRDL 4 ppm | 2025 Source |
| Total trihalomethanes (TTHM) | 19.00 ppbReported running annual averageIndividual range: 5.06–30.53 ppb | MCL 80 ppb | 2025 Source |
| Haloacetic acids (HAA5)Annual averages can include prior-year quarters. | 21.44 ppbReported running annual averageIndividual range: 3.26–18.45 ppb | MCL 60 ppb | 2025 Source |
| Lead · household taps · Jul–DecOne sampled site exceeded the action level; the report marks no system action-level exceedance. | 1.5 ppb90th percentileIndividual range: ND–47.8 ppb | Action level 15 ppb | 2025 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chloramines | 3.2 ppmReported annual compliance resultIndividual range: 0.2–5.3 ppm | MRDL 4 ppm | 2025 Source |
| TTHM | 45.7 ppbReported annual compliance resultIndividual range: 11.9–41.8 ppb | MCL 80 ppb | 2025 Source |
| HAA5 | 33.1 ppbReported annual compliance resultIndividual range: 8.4–31.7 ppb | MCL 60 ppb | 2025 Source |
| Lead · household taps | 0.75 ppb90th percentileIndividual range: ND–12 ppb | Action level 15 ppb | 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chloramines | 3.8 ppmReported annual compliance resultIndividual range: 0.03–6.8 ppm | MRDL 4 ppm | 2025 Source |
| TTHM | 17.2 ppbReported annual compliance resultIndividual range: 7.1–21.2 ppb | MCL 80 ppb | 2025 Source |
| HAA5 | 12.1 ppbReported annual compliance resultIndividual range: 1.9–6.7 ppb | MCL 60 ppb | 2025 Source |
| Lead · household taps | 0.66 ppb90th percentileIndividual range: ND–1.3 ppb | Action level 15 ppb | 2023 Source |
| E. coli · compliance eventA total-coliform-positive repeat followed an E. coli-positive routine sample. The county reports subsequent negative E. coli samples and completion of four corrective actions after a Level 2 assessment. This historical event is not a current boil-water notice. | MCL violation reported August event | See source explanation | 2025 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine and chloramines | 3.8 ppmHighest running annual averageIndividual range: 0.30–5.30 ppm | MRDL 4 ppm | 2025 Source |
| TTHM | 41.553 ppbHighest locational running annual averageIndividual range: 31.40–48.63 ppb | MCL 80 ppb | 2025 Source |
| HAA5 | 28.113 ppbHighest locational running annual averageIndividual range: 13.35–35.03 ppb | MCL 60 ppb | 2025 Source |
| Lead · household tapsOne sampled site exceeded the action level; the report marks no system action-level exceedance. | 0.8 ppb90th percentile | Action level 15 ppb | 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine and chloramines | 3.44 ppmHighest running annual averageIndividual range: 0.6–5.8 ppm | MRDL 4 ppm | 2025 Source |
| TTHM | 21.2 ppbHighest locational running annual averageIndividual range: 3.5–39.4 ppb | MCL 80 ppb | 2025 Source |
| HAA5 | 11.7 ppbHighest locational running annual averageIndividual range: 0.3–11.3 ppb | MCL 60 ppb | 2025 Source |
| Lead · household taps | ND ppb90th percentile · June | Action level 15 ppb | 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine | 1.4 ppmHighest average of quarterly averagesIndividual range: 0.4–1.8 ppm | MRDL 4 ppm | 2025 Source |
| TTHM | 67.6 ppbHighest locational four-quarter averageIndividual range: 48.7–76.9 ppb | MCL 80 ppb | 2025 Source |
| HAA5 | 8.0 ppbHighest locational four-quarter averageIndividual range: 4.34–10.7 ppb | MCL 60 ppb | 2025 Source |
| Lead · household tapsNo sampled sites exceeded the action level. | 1.0 ppb90th percentile · June | Action level 15 ppb | 2025 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chloramines | 3.4 ppmReported compliance averageIndividual range: 1.6–4.1 ppm | MRDL 4 ppm | 2024 Source |
| Haloacetic acids (HAA5) | 29.5 ppbReported compliance valueIndividual range: 17.7–34.6 ppb | MCL 60 ppb | 2024 Source |
| Total trihalomethanes (TTHM) | 60.4 ppbReported compliance valueIndividual range: 34.1–75.4 ppb | MCL 80 ppb | 2024 Source |
| Lead · household tapsNo sampled sites exceeded the action level. | 1.2 ppb90th percentile · August–September | Action level 15 ppb | 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine & chloraminesThe report includes a May free-chlorine flush. | 3.4 ppmHighest running annual averageIndividual range: 0.6–4.0 ppm | MRDL 4 ppm | 2025 Source |
| Haloacetic acids (HAA5) | 12.40 ppbHighest locational running annual averageIndividual range: 0.6–16.9 ppb | MCL 60 ppb | 2025 Source |
| Total trihalomethanes (TTHM) | 19.50 ppbHighest locational running annual averageIndividual range: ND–30 ppb | MCL 80 ppb | 2025 Source |
| Lead · household tapsOne sampled site exceeded the action level; the report lists no system action-level violation. | 1.1 ppb90th percentile · August | Action level 15 ppb | 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chloramines | 2.3 ppmReported compliance valueIndividual range: 0.5–5.2 ppm | MRDL 4 ppm | 2025 Source |
| Haloacetic acids (HAA5)Individual samples differ from the compliance value. The source’s explanatory paragraph contains inconsistent figures; these are its table values. | 44 ppbReported compliance valueIndividual range: 9.3–107 ppb | MCL 60 ppb | 2025 Source |
| Total trihalomethanes (TTHM)Individual samples differ from the compliance value. The source’s explanatory paragraph contains inconsistent figures; these are its table values. | 76 ppbReported compliance valueIndividual range: 31.3–164 ppb | MCL 80 ppb | 2025 Source |
| Lead · household tap samplingFour sampled sites exceeded the action level; the system’s 90th-percentile result did not. | 9.6 ppb90th percentile | Action level 15 ppb in report | June 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine | 1.6 ppmReported compliance valueIndividual range: 0.8–2.2 ppm | MRDL 4 ppm | 2025 Source |
| Haloacetic acids (HAA5) | 6 ppbReported compliance valueIndividual range: 1.9–6.9 ppb | MCL 60 ppb | 2025 Source |
| Total trihalomethanes (TTHM) | 18 ppbReported compliance valueIndividual range: 12–22 ppb | MCL 80 ppb | 2025 Source |
| Lead · household tap samplingNo sampled sites exceeded the action level. | 3.0 ppb90th percentile | Action level 15 ppb in report | June 2023 Source |
Selected results from your utility’s report
| Substance / indicator | Reported result | Benchmark in source | Sample year / source |
|---|---|---|---|
| Chlorine and chloramines | 2.6 ppmReported compliance valueIndividual range: 0.6–5.4 ppm | MRDL 4 ppm | 2025 Source |
| Haloacetic acids (HAA5) | 27.45 ppbReported levelIndividual range: 26.4–28.5 ppb | MCL 60 ppb | August 2025 Source |
| Total trihalomethanes (TTHM) | 22.3 ppbReported levelIndividual range: 22.1–22.5 ppb | MCL 80 ppb | August 2025 Source |
| Lead · household tap samplingOne sampled site exceeded the action level; the system’s 90th-percentile result did not. | 6.08 ppb90th percentile | Action level 15 ppb in report | July–August 2023 Source |
City of Fort Worth
2025 data; lead and copper 2025
Results for City of Fort Worth customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | 108–150 mg/L as CaCO₃Range in secondary-constituent table | 2025View source ↗ | Moderately hard to hardThe range crosses the USGS hard-water threshold of 121 mg/L; hardness concerns scale and spotting, not a health violation. |
| Chloramine | 3.3 ppm“Your water” value in the results table; range 0.93–4.7 ppm | 2025View source ↗ | Report lists no violation; benchmark 4 ppm MRDLChloramine is used for disinfection. A filtration system targeting it needs the appropriate media and contact time; a single sample is not the same as the regulated annual measure. |
| Total trihalomethanes (TTHM) | 13.8 ppbUtility-reported “Your water” result; not the maximum sample | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 9.3 ppbUtility-reported “Your water” result; not the maximum sample | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | 0.7 ppmUtility-reported “Your water” result | 2025View source ↗ | Below 4 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Nitrate as nitrogen | 0.7 ppmUtility-reported “Your water” result | 2025View source ↗ | Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Lead | 3.1 ppb90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.42 ppm90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Arlington
2025 data; lead and copper 2023
Results for City of Arlington customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | 94 average mg/L as CaCO₃Annual reported average; range 80.4–110 mg/L; utility gives 5.5 gpg average | 2025View source ↗ | Moderately hardAll of the reported range falls in the USGS moderately hard category; a softener targets mineral scale, not chlorine taste. |
| Chloramine | 3.7 average ppmReported annual average of routine-site samples | 2025View source ↗ | Below 4 ppm MRDLChloramine residual is present below the report’s annual benchmark; choose filtration specifically configured for chloramine if that is the target. |
| Total trihalomethanes (TTHM) | 11.5 average ppbReported annual average of routine-site samples | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 7.8 average ppbReported annual average of routine-site samples | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | 0.52 average ppmReported average; highest sample 0.77 ppm | 2025View source ↗ | Below 4 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Nitrate | 0.370 average ppmReported average; highest sample 0.844 ppm | 2025View source ↗ | Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Lead | 1.3 ppb90th-percentile tap sampling result; zero sites above the action level | 2023View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.175 ppm90th-percentile tap sampling result; zero sites above the action level | 2023View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Plano
2025 city and supplier data
Results for City of Plano customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | Wylie: 96–200; Leonard: 96–144 mg/L as CaCO₃Ranges from NTMWD treatment plants; not city distribution or home measurements | 2025View source ↗ | Moderately hard to very hard (Wylie); moderately hard to hard (Leonard)The supplier ranges reach hard or very hard levels, supporting a softener recommendation for scale control; measure your incoming water to size and set it correctly. |
| Chloramine | 2.59 ppmAverage of quarterly data; individual samples 0.38–4.00 ppm | 2025View source ↗ | Below 4 ppm MRDLChloramine is the distribution disinfectant; use the correct filter configuration if reducing chloramine is a goal. |
| Total trihalomethanes (TTHM) | 63.9 ppbHighest detected result as labelled in the city report; not a supplied LRAA | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 38.1 ppbHighest detected result as labelled in the city report; not a supplied LRAA | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | Wylie 0.492; Leonard 0.225 ppmHighest detected supplier results, not Plano tap samples | 2025View source ↗ | Below 4 ppm MCL comparisonThe report lists fluoride separately for two supplying plants; whole-home carbon filtration is not the same as dedicated fluoride treatment. |
| Nitrate as nitrogen | 0.704 ppmHighest city distribution result | 2025View source ↗ | Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Lead | 1.4 ppb90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.987 ppm90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Frisco
2025 data; lead and copper sampled July 28, 2023
Results for City of Frisco customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | Wylie: 96–200; Leonard: 96–144 mg/L as CaCO₃Ranges from NTMWD treatment plants; not city distribution or home measurements | 2025View source ↗ | Moderately hard to very hard (Wylie); moderately hard to hard (Leonard)The supplier ranges reach hard or very hard levels, supporting a softener recommendation for scale control; measure your incoming water to size and set it correctly. |
| Chloramine | 2.16 ppmReported quarterly-data value; individual samples0.3–3.86 ppm | 2025View source ↗ | Below 4 ppm MRDL comparisonThe utility uses chloramine; reducing it requires a filter configured for that disinfectant. |
| Total trihalomethanes (TTHM) | 36 ppbReport’s compliance value labelled Highest Level Detected; separate individual range shown | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 22 ppbReport’s compliance value labelled Highest Level Detected; separate individual range shown | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | Wylie 0.492; Leonard 0.225 ppmHighest detected NTMWD supplier results | 2025View source ↗ | Below 4 ppm MCL comparisonThese are supplier-plant measurements and are not a fluoride test at an individual Frisco tap. |
| Nitrate as nitrogen | Wylie 0.866; Leonard 0.065 ppmHighest detected NTMWD supplier results | 2025View source ↗ | Below 10 ppm MCL comparisonBoth supplier values are below the report’s nitrate benchmark; do not present them as city distribution samples. |
| Lead | 2.31 ppb90th-percentile tap sampling result; zero sites above the action level | July 28, 2023View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.455 ppm90th-percentile tap sampling result; zero sites above the action level | July 28, 2023View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of McKinney
2025 city data with supplier values individually dated
Results for City of McKinney customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | Wylie: 96–200; Leonard: 96–144 mg/L as CaCO₃Ranges from NTMWD treatment plants; not city distribution or home measurements | 2025View source ↗ | Moderately hard to very hard (Wylie); moderately hard to hard (Leonard)The supplier ranges reach hard or very hard levels, supporting a softener recommendation for scale control; measure your incoming water to size and set it correctly. |
| Chloramine | 2.22 ppmCity average of quarterly data; individual samples0.2–3.8 ppm | 2025View source ↗ | Below 4 ppm MRDLThe 0.2 ppm sample occurred during annual chlorine maintenance, when ammonia addition temporarily stops; ordinary treatment uses chloramine. |
| Total trihalomethanes (TTHM) | 35.4 ppbHighest locational running annual average | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 20.5 ppbHighest locational running annual average | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | Wylie 0.492; Leonard 0.225 ppmHighest detected NTMWD supplier results | 2025View source ↗ | Below 4 ppm MCL comparisonThese values are measured at supplying plants, not individual McKinney homes. |
| Nitrate as nitrogen | 0.397 ppmHighest city distribution result | 2025View source ↗ | Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Lead | 0.903 ppb90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.787 ppm90th-percentile tap sampling result; zero sites above the action level | 2025View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Denton
2025 data; lead and copper2024
Results for City of Denton customers. Confirm the retail utility and system on your bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Water hardness | Not quantified mg/L as CaCO₃No hardness measurement provided in the reviewed municipal CCR | 2025 report reviewedView source ↗ | Unknown—not zeroThe report does not establish whether your incoming water is hard; obtain a hardness test before setting a softener. |
| Chloramine | 3.21 average ppmReported average; single samples0.08–4.50 ppm | 2025View source ↗ | Below 4 ppm annual MRDL comparisonChloramine is used for disinfection; the annual measure and individual sample maximum are different. |
| Total trihalomethanes (TTHM) | 13 ppbMaximum locational running annual average | 2025View source ↗ | Below 80 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Haloacetic acids (HAA5) | 11 ppbMaximum locational running annual average; report prints HAAS | 2025View source ↗ | Below 60 ppb comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Fluoride | 0.51 average ppmReported average; maximum 0.723 ppm | January 15, 2025View source ↗ | Below 4 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Nitrate | 0.339 average ppmReported average; maximum 0.364 ppm | January 15, 2025View source ↗ | Below 10 ppm comparisonBelow the report’s stated benchmark; this does not mean absent or describe an individual tap. |
| Lead | 1.5 ppb90th-percentile tap sampling result; zero sites above the action level | 2024View source ↗ | Below 15 ppb action levelThis system-level sampling statistic is not a result for your home; plumbing can affect lead at an individual tap. |
| Copper | 0.6335 ppm90th-percentile tap sampling result; zero sites above the action level | 2024View source ↗ | Below 1.3 ppm action levelBelow the action level used in this report; this is not a measurement at every customer’s tap. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
Austin Water
2025 report; each row keeps its measurement year
Results for Austin Water customers on system TX2270001. Other districts and private wells need their own reports.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 93 mg/L as CaCO₃ Annual average; range 70–126 | 2025View source ↗ | Moderately hard · USGS: moderately hard 61–120 mg/LScale-related measure; not a health limit. |
| Chloramines | 2.3 ppm Distribution-system average; range 0.06–3.1 | 2025View source ↗ | Below stated benchmark · MRDL 4 ppmMatch treatment to chloramine rather than assuming a chlorine-only claim applies. |
| Total trihalomethanes (TTHM) | 45.5 ppb Highest locational running annual average; individual range 31.4–53.9 | 2025View source ↗ | Below limit · MCL 80 ppb, LRAA basis |
| Haloacetic acids (HAA5) | 15.6 ppb Highest locational running annual average; individual range 8.4–21.1 | 2025View source ↗ | Below limit · MCL 60 ppb, LRAA basis |
| Fluoride | 0.71 ppm Highest treatment-plant result; average 0.66, range 0.59–0.71 | 2025View source ↗ | Below limit · MCL 4 ppm |
| Nitrate as nitrogen | 0.11 ppm Highest treatment-plant result; average 0.05, range 0–0.11 | 2025View source ↗ | Below limit · MCL 10 ppm |
| Lead | <1.0 ppb 90th-percentile tap sampling; no sample over 15 ppb | 2024View source ↗ | Below action level · Report action level 15 ppb; MCLG 0Not a guarantee for a particular home's plumbing. |
| Copper | <0.008 ppm 90th-percentile tap sampling; no sample over 1.3 ppm | 2024View source ↗ | Below action level · Action level 1.3 ppmA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Round Rock
2025 report; each row keeps its measurement year
Results for City of Round Rock customers on system TX2460003. Other districts and private wells need their own reports.
The 2025 results table reports average hardness of 258 mg/L (range 100–358); the narrative elsewhere in the same report says 249 mg/L. Both are very hard. This summary uses the dated results table and retains the discrepancy. Lead/copper entries are omitted because the report's numbers, units and exceedance counts are internally inconsistent.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 258 mg/L Results-table average; range 100–358 | 2025View source ↗ | Very hard · USGS very hard: over 180 mg/L as CaCO₃Narrative separately says 249; use a home test for equipment settings. |
| Chloramine | 2.15 ppm Average; range 1.80–2.41 | 2025View source ↗ | Below stated benchmark · MRDL 4 ppm |
| Total trihalomethanes (TTHM) | 65 ppb Maximum LRAA; individual range 28.7–94.5 | 2025View source ↗ | Below limit · MCL 80 ppb, LRAA basisA single result of 94.5 is not the annual compliance value. |
| Haloacetic acids (HAA5) | 21 ppb Maximum LRAA; individual range 6.8–36.2 | 2025View source ↗ | Below limit · MCL 60 ppb, LRAA basis |
| Fluoride | 0.21 ppm Reported high, low and average all 0.21 | 2025View source ↗ | Below limit · MCL 4 ppm |
| Nitrate as nitrogen | 1.63 ppm Highest result; first results table range <0.25–1.63 | 2025View source ↗ | Below limit · MCL 10 ppm |
| Barium | 0.0545 ppm Highest result; range 0.0442–0.0545 | 2025View source ↗ | Below limit · MCL 2 ppm |
| Total dissolved solids | 302 ppm Reported high, low and average all 302 | 2025View source ↗ | Below reported secondary limit · Report secondary limit 1,000 ppmAn aesthetic benchmark, not a health or filtration performance claim. |
| Lead | Not verified No verified lead number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Georgetown Water Utility
2025 report; each row keeps its measurement year
Results for City of Georgetown Water Utility customers on system TX2460001. Other districts and private wells need their own reports.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 176–178 or 309–320 mg/L as CaCO₃ Two plant-system bands; not one system-wide average | May 8, 2026 utility guidance, historical plant dataView source ↗ | Hard to very hard · USGS hard 121–180; very hard >180 |
| Total chlorine | 3 ppm Average; range 0.06–4.54 | 2025View source ↗ | Average below benchmark · MRDL 4 ppmUtility normally uses chloramine. A single maximum is not by itself the compliance calculation. |
| Total trihalomethanes (TTHM) | 73.65 ppb Highest LRAA; individual range 14.5–125.3 | 2025View source ↗ | Below limit in 2025 · MCL 80 ppb, LRAA basisAnnual historical result, not current advisory status. |
| Haloacetic acids (HAA5) | 39.83 ppb Highest LRAA; individual range 3.7–75.7 | 2025View source ↗ | Below limit in 2025 · MCL 60 ppb, LRAA basis |
| Fluoride | 0.2 ppm Highest result; average 0.19, range 0.02–0.2 | 2025View source ↗ | Below limit · MCL 4 ppmReport says fluoride is not added by the City. |
| Nitrate as nitrogen | 3.19 ppm Highest result; average 1.11, range 0.08–3.19 | 2025View source ↗ | Below limit · MCL 10 ppm |
| Lead | <2.2 ppb 90% of samples below 2.2; one sample reached 24 ppb and exceeded 15 | 2023View source ↗ | 90th percentile below action level · Report action level 15 ppb; MCLG 0One home sampling result exceeded the action level; this is not a guarantee for an individual tap. |
| Copper | <0.18 ppm 90% of samples below 0.18; range 0.002–1.1; no samples over 1.3 | 2023View source ↗ | Below action level · Action level 1.3 ppmA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Kyle
2025 report; each row keeps its measurement year
Results for City of Kyle customers on system TX1050002. Other districts and private wells need their own reports.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 275–295 mg/L as CaCO₃ Reported hardness range, varies with groundwater use | 2025 reportView source ↗ | Very hard · USGS very hard: >180 mg/L |
| Free chlorine | 1.43 ppm City-system average; range 0.55–2.8 | 2025View source ↗ | Below stated benchmark · MRDL 4 ppm |
| Total trihalomethanes (TTHM) | 67 ppb Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; site's individual range 47.3–83.8 | 2025View source ↗ | Below limit · MCL 80 ppb, LRAA basis |
| Haloacetic acids (HAA5) | 25 ppb Highest LRAA among Kyle's four listed sites, 310 Ayers Rd; range 14–48 | 2025View source ↗ | Below limit · MCL 60 ppb, LRAA basis |
| Fluoride | 1.83 ppm Highest reported City-system result | January 8, 2025View source ↗ | Below primary limit · MCL 4 ppmNaturally occurring; Kyle says it does not add fluoride. |
| Nitrate as nitrogen | 1.83 ppm Highest reported result; range 0–1.83 | January 8, 2025View source ↗ | Below limit · MCL 10 ppm |
| Lead | 1.91 ppb 90th percentile; range 0–3.9; zero sites above action level | 2023–2025 monitoring periodView source ↗ | Below action level · Report action level 15 ppb; MCLG0A system sampling percentile is not a measurement of your faucet. |
| Copper | 0.0975 ppm 90th percentile; range 0.00279–0.241; zero sites above action level | 2023–2025 monitoring periodView source ↗ | Below action level · Action level 1.3 ppmA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of San Marcos
2025 report; each row keeps its measurement year
Results for City of San Marcos customers on system TX1050001. Other districts and private wells need their own reports.
The 2025 report records a TTHM running-annual-average violation for October 1–December 31, 2025. The City's December 5, 2025 notice identifies81 ppb at345 Champions Blvd versus an80 ppb MCL and describes corrective flushing, source changes and extra sampling. This is historical reporting, not a live advisory.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 269 mg/L as CaCO₃ Average; range 236–302; 2025 report has no replacement figure | 2024View source ↗ | Very hard, historical result · USGS very hard: >180 mg/L |
| Free chlorine | 1.26 ppm Average; range 0.30–2.42 | 2025View source ↗ | Below stated benchmark · MRDL 4 ppm |
| Total trihalomethanes (TTHM) | 81 ppb Highest LRAA; individual range 1.1–94.3 ppb | 2025; Q4 violationView source ↗ | Above limit in 2025 · MCL 80 ppb, LRAA basisOfficial notice confirms0.081 mg/L=81 ppb. CCR unit/No-violation cells conflict with its own violation section; use the official notice for this interpretation. |
| Haloacetic acids (HAA5) | 25 ppb Highest LRAA; City of Kyle report's purchased-water San Marcos table confirms units and value | 2025View source ↗ | Below limit · MCL 60 ppb, LRAA basisSan Marcos CCR prints ppm in HAA5 cell; corroborating official supplier-results table usesppb. |
| Fluoride | 0.21 ppm Highest result; range 0.16–0.21 | January 7, 2025View source ↗ | Below limit · MCL 4 ppm |
| Nitrate | 1.77 ppm Highest result; range 1.16–1.77 | January 7, 2025View source ↗ | Below limit · MCL 10 ppm |
| Lead | 1.63 ppb 90th percentile; range 0–2.22; zero sites over AL | 2022–2024 monitoring periodView source ↗ | Below action level · Report action level 15 ppb; MCLG0A system sampling percentile is not a measurement of your faucet. |
| Copper | 0.171 ppm 90th percentile; range 0.0133–0.31; zero sites over AL | 2022–2024 monitoring periodView source ↗ | Below action level · Action level 1.3 ppmA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
Sugar Land — Main System
2025 report; each row keeps its measurement year
Main System only. River Park, Greatwood and New Territory have separate systems and results. City's undated water-quality page gives Main System range 35–280 ppm (2.0–16.4 gpg). Do not treat this broader range as 2025 report range.
The report includes a Main System surface-water monitoring/reporting violation for January 2026 after a process-water line break. This is a monitoring violation, not proof of a contaminant exceedance at your tap. It also lists one cyanide maximum above the printed MCL while reporting no violation; do not make an all-results-below claim.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 104 mg/L as CaCO₃Reported average; listed minimum and maximum both 104 | 2025View source ↗ | Moderately hardA scale-related measure, not a health-based limit. |
| Chloramine | 2.74 mg/L Average; range 0.50–3.96 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 5.9 µg/L Highest average; individual range 0–7.8 | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| HAA5 | 5.5 µg/L Highest average; individual range 0–9.9 | 2025View source ↗ | Below MCL · MCL 60 µg/L |
| Fluoride | 0.17 mg/L Highest detected | 2025View source ↗ | Below MCL · MCL 4 mg/L |
| Nitrate as nitrogen | 3.31 mg/L Highest detected; range 0–3.31 | 2025View source ↗ | Below MCL · MCL 10 mg/L |
| Lead | 2.54 µg/L 90th percentile; range 0–12.6 | 2021–2023View source ↗ | 90th percentile below action level; not a home test · Report action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.291 mg/L 90th percentile; range 0.0319–0.443 | 2021–2023View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| Cyanide | 310 µg/L Highest individual level; range 0–310 | 2025View source ↗ | Sample maximum above printed MCL; report marks no violation. Ask utility about compliance statistic; not an independent violation finding. · Printed MCL 200 µg/L |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
Sugar Land — River Park System
2025 report; each row keeps its measurement year
River Park system only. Undated city page range 109–155 ppm; separate from latest CCR point measurement.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 104 mg/L as CaCO₃Reported average, minimum and maximum 104 | 2025View source ↗ | Moderately hardA scale-related measure, not a health-based limit. |
| Free chlorine | 1.62 mg/L Average; range 0.50–2.15 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 2.5 µg/L Reported average, minimum and maximum 2.5 | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| Fluoride | 0.42 mg/L Highest detected | 2023View source ↗ | Below MCL · MCL 4 mg/L |
| Barium | 0.151 mg/L Highest detected | 2025View source ↗ | Below MCL · MCL 2 mg/L |
| Lead | 0.519 µg/L 90th percentile; range 0–1.04 | 2022–2024View source ↗ | 90th percentile below action level · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.102 mg/L 90th percentile; range 0.00775–2.18; one site above action level | 2022–2024View source ↗ | 90th percentile below action level; one individual site exceeded · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| HAA5 | Not verified No verified haa5 number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
| Nitrate | Not verified No verified nitrate number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
Sugar Land — New Territory System
2025 report; each row keeps its measurement year
New Territory system only. Undated city page range 50–186 ppm. Current tap test may differ from this53.8 ppm report result.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 53.8 mg/L as CaCO₃Reported average, minimum and maximum 53.8 | 2025View source ↗ | SoftA scale-related measure, not a health-based limit. |
| Free chlorine | 1.55 mg/L Average; range 0.78–1.95 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 2.2 µg/L Highest average; individual range 0–3.9 | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| Fluoride | 0.54 mg/L Highest detected; range 0.22–0.54 | 2023View source ↗ | Below MCL · MCL 4 mg/L |
| Nitrate as nitrogen | 0.11 mg/L Highest detected; range 0–0.11 | 2025View source ↗ | Below MCL · MCL 10 mg/L |
| Lead | 0.229 µg/L 90th percentile; range 0–0.59 | 2021–2023View source ↗ | 90th percentile below action level · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.223 mg/L 90th percentile; range 0.00611–0.451 | 2021–2023View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| HAA5 | Not verified No verified haa5 number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
Sugar Land — Greatwood System
2025 report; each row keeps its measurement year
Greatwood system only. Undated city page range 34–164 ppm; separate from2024 measurement range.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 103.2 mg/L as CaCO₃2024 average in 2025 CCR | 2024View source ↗ | Moderately hardA scale-related measure, not a health-based limit. |
| Free chlorine | 1.59 mg/L Average; range 0.87–2.02 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 4.0 µg/L Highest average; range 0–6.4 | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| Fluoride | 1.5 mg/L Highest detected; range 0.51–1.5 | 2025View source ↗ | Below MCL · MCL 4 mg/L |
| Arsenic | 4.3 µg/L Highest detected; range 2.4–4.3 | 2024View source ↗ | Below enforceable MCL; above zero health goal · MCL 10 µg/L; MCLG0 |
| Lead | 0.511 µg/L 90th percentile; range 0–0.951 | 2023–2025View source ↗ | 90th percentile below action level · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.151 mg/L 90th percentile; range 0.0103–0.306 | 2023–2025View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| HAA5 | Not verified No verified haa5 number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
| Nitrate | Not verified No verified nitrate number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
The Woodlands MUD No.1
2025 report; each row keeps its measurement year
Applies only to The Woodlands MUD1, not every Woodlands MUD or Creekside Park. Use Woodlands Water's Find Your MUD tool and the report for the exact district on the bill.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not verified No confirmed numerical hardness value used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowUnknown hardness is not zero. A current incoming-water test can guide softening. |
| Free chlorine | 1.91 mg/L Average; range 0.45–3.66 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 41 µg/L Highest listed LRAA, DBP2-01; sampled range 31.9–42.4 at that site | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| HAA5 | 15 µg/L Highest listed LRAA, DBP2-01; range 8.3–15 at that site | 2025View source ↗ | Below MCL · MCL 60 µg/L |
| Nitrate | 0.21 mg/L Highest detected; range 0–0.21 | 2025-02-27View source ↗ | Below MCL · MCL 10 mg/L |
| Lead | 1.07 µg/L 90th percentile; range 0–10.7; zero sites above AL | 2021–2023View source ↗ | 90th percentile below action level · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.252 mg/L 90th percentile; range 0.0274–0.901 | 2021–2023View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| Fluoride — SJRA supplier | 0.43 mg/L Supplier TX1700197 highest value; range 0.17–0.43; separate appendix | 2025View source ↗ | Below MCL; supplier result, not MUD tap sample · MCL 4 mg/L |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Conroe
2025 report; each row keeps its measurement year
City of Conroe municipal system; surrounding MUDs and private wells have separate reports.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not verified No confirmed numerical hardness value used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowUnknown hardness is not zero. A current incoming-water test can guide softening. |
| Chlorine | 0.97 mg/L Average; range 0.70–1.50 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 33.8 µg/L Highest listed LRAA,36Village Hill; range 20–33.8 at that site | 2025View source ↗ | Below MCL · MCL 80 µg/L |
| HAA5 | 15.9 µg/L Highest listed LRAA,110Baretta; range<6–15.9 at that site | 2025View source ↗ | Below MCL · MCL 60 µg/L |
| Fluoride | 0.22 mg/L Highest detected; range 0–0.22 | 2025-03-24View source ↗ | Below MCL · MCL 4 mg/L |
| Nitrate | 0.42 mg/L Highest detected; range 0–0.42 | 2025-11-17View source ↗ | Below MCL · MCL 10 mg/L |
| Lead | 0 µg/L reported 90th percentile; range 0–1.5; not zero at every tap | 2023–2025View source ↗ | 90th percentile below action level · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.275 mg/L 90th percentile; range 0.00143–0.677 | 2023–2025View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
City of Pearland
2025 report; each row keeps its measurement year
Only City of Pearland water-system customers should use the linked municipal report. A mailing address or county name does not confirm your utility.
The official 2025 report was identified, but its numeric tables could not be retrieved for independent verification. “Not verified” describes this summary, not the utility’s reporting. Open the original report for its complete measurements.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Not verified No confirmed numerical hardness value used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowUnknown hardness is not zero. A current incoming-water test can guide softening. |
| Disinfectant | Not verified No verified disinfectant number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| TTHMs | Not verified No verified tthms number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| HAA5 | Not verified No verified haa5 number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| Fluoride | Not verified No verified fluoride number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| Lead | Not verified No verified lead number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
| Nitrate | Not verified No verified nitrate number used in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowNo result shown does not mean absent. Check the linked report or obtain relevant testing. |
City of League City
2026 report with 2025 data; individual rows keep their dates
Municipal utility results; supplier EP002 hardness is separately labelled. Galveston County is not one water system.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 124 mg/L as CaCO₃SEWPP supplier/entry point EP002 only in 2026 report; min/avg/max124 | 2025View source ↗ | Hard — entry-point resultDo not label citywide tap hardness. Report has multiple supplies/groundwater wells. Verify home's current blend. |
| Chloramine | 2.39 mg/L Average; range 0.50–3.63 | 2025View source ↗ | Average below MRDL · MRDL 4 mg/L |
| TTHM | 46.9 µg/L Highest level reported; range 22.9–46.9; source does not identify this column as LRAA | 2025View source ↗ | Reported maximum below MCL; compliance uses required averaging · MCL 80 µg/L |
| HAA5 | 34 µg/L Highest level reported; range 14.1–34 | 2025View source ↗ | Reported maximum below MCL · MCL 60 µg/L |
| Fluoride | 0.20 mg/L Highest municipal value; distinct from supplier0.21 | 2025-03-17View source ↗ | Below MCL · MCL 4 mg/L |
| Nitrate | 0.89 mg/L Highest municipal value; range 0.08–0.89 | 2025-03-17View source ↗ | Below MCL · MCL 10 mg/L |
| Lead | 3 µg/L 90th percentile; range 0–58; one site above action level | 2022–2024View source ↗ | 90th percentile below action level; one individual site exceeded · Action level 15 µg/LA system sampling percentile is not a measurement of your faucet. |
| Copper | 0.464 mg/L 90th percentile; range 0.0033–1.08 | 2022–2024View source ↗ | 90th percentile below action level · Action level 1.3 mg/LA system sampling percentile is not a measurement of your faucet. |
| PFAS | Not verified No compound-specific result assessed in this summary | 2025 report reviewView source ↗ | Cannot assess high or lowThis does not establish whether PFAS are present or absent. Check compound-specific testing before choosing treatment. |
Houston Water — Main System
2025 report; individual rows show sample year
The 2025 Main System report lists a May turbidity treatment-technique violation and a September chlorite monitoring violation. These are historical notices, not a live advisory. Follow current utility instructions for any service or water-quality alert.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 135.5 mg/L as CaCO₃ · average | 2025 | Hard average; wide rangeRange: 43.5–229 mg/L (2.5–13.4 gpg), from soft to very hard. Average: 7.9 gpg. |
| Chloramine | 2.8 ppmAverage; samples 0.04–4.8 | 2025 | Average below 4 ppm MRDLIndividual peaks and annual compliance averages are different. |
| TTHMs | 43.6 ppbHighest locational running annual average | 2025 | Below 80 ppb MCL |
| HAA5 | 40.8 ppbHighest locational running annual average | 2025 | Below 60 ppb MCL |
| Fluoride | 0.71 ppmMaximum; average 0.11 | 2025 | Below 4 ppm MCL |
| Lead | 5.1 ppb90th percentile; 0 sites over action level | 2025 | Below 15 ppb action levelA utility percentile is not a test of your faucet. |
| PFAS | Not quantified here No compound-specific result used in this summary | 2025 report | Cannot assess high or lowNo result shown does not mean absent. |
| Nitrate as nitrogen | 1.40 ppmMaximum in distribution samples | 2025 | Below 10 ppm MCL |
| Arsenic | 6.7 ppbMaximum at water plants | 2025 | Below 10 ppb MCL |
| Barium | 0.40 ppmMaximum | 2025 | Below 2 ppm MCL |
| Copper | 0.22 ppm90th percentile | 2025 | Below 1.3 ppm action level |
| Total dissolved solids | 260 ppmAverage; range 146–331 | 2025 | Below 500 ppm aesthetic guideline |
| Turbidity | 1.95 NTUHighest single measurement | 2025 | Report lists a treatment-technique violationSee the utility notice on page 9. |
Dallas Water Utilities
2025 report; hardness from December 2023 memo
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 120–155 mg/L as CaCO₃ · published range | December 2023 utility memo | Moderately hard to hard7.0–9.1 gpg. This older utility guidance is useful context, not a 2025 measurement or a test of your home. |
| Chloramine / total chlorine | 2.97 ppmAverage total chlorine residual; range 2.75–3.18 | 2025 | Average below 4 ppm MRDL |
| TTHMs | 19.7 ppbHighest locational running annual average | 2025 | Below 80 ppb MCL |
| HAA5 | 15.1 ppbHighest locational running annual average | 2025 | Below 60 ppb MCL |
| Fluoride | 0.686 ppmMaximum; average 0.627 | 2025 | Below 4 ppm MCL |
| Lead | 1.1 ppb90th percentile; 0 sites over action level | 2024 | Below 15 ppb action levelAn individual home may differ. |
| PFAS | Not quantified here No compound-specific result used in this summary | 2025 report | Cannot assess high or lowAsk DWU for current PFAS monitoring. |
| Nitrate as nitrogen | 0.802 ppmMaximum; average 0.671 | 2025 | Below 10 ppm MCL |
| Barium | 0.038 ppmMaximum | 2025 | Below 2 ppm MCL |
| Copper | 0.39 ppm90th percentile | 2024 | Below 1.3 ppm action level |
| Cyanide | 76.8 ppbMaximum | 2025 | Below 200 ppb MCL |
| Atrazine | 0.10 ppbMaximum | 2025 | Below 3 ppb MCL |
| Turbidity | 0.16 NTUHighest single measurement | 2025 | Below 1 NTU single-measurement criterion |
San Antonio Water System — Main System
2026 report using 2025 data; 2024 lead samples
TTHM source needs clarification: the report prints 86.2 ppb against an 80 ppb MCL, but also marks “No” violation and says no 2025 violations. We show the number and flag the conflict rather than declaring a violation or a clean pass. Ask SAWS to confirm the reporting basis.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 15–20 gpg · utility’s typical range | Current SAWS FAQ; sampling year not specified | Very hardApproximately 257–342 mg/L as CaCO₃. Above the USGS very-hard threshold of 180 mg/L. This is utility guidance, not a tap measurement. |
| Free chlorine | 1.46 ppmAverage; range 0.16–3.7 | 2025 | Average below 4 ppm MRDL |
| TTHMs | 86.2 ppbReported highest level; report marks no violation | 2025 | Above 80 ppb comparison; clarification neededThe number and the report’s compliance statement conflict. |
| HAA5 | 30.6 ppbReported highest level | 2025 | Below 60 ppb MCL |
| Fluoride | 0.69 ppmMaximum; range <0.5–0.69 | 2025 | Below 4 ppm MCL |
| Lead | 1.6 ppb90th percentile; 0 sites over action level | 2024 | Below 15 ppb action levelA utility percentile does not rule out lead at your tap. |
| PFAS | Not quantified here No compound-specific result used in this summary | 2026 report | Cannot assess high or lowAsk SAWS for the current PFAS monitoring results. |
| Nitrate as nitrogen | 2.45 ppmMaximum | 2025 | Below 10 ppm MCL |
| Barium | 0.125 ppmMaximum | 2025 | Below 2 ppm MCL |
| Copper | 0.187 ppm90th percentile | 2024 | Below 1.3 ppm action level |
| Selenium | 3.1 ppbMaximum | 2025 | Below 50 ppb MCL |
| Combined radium 226/228 | 1.5 pCi/LMaximum | 2025 | Below 5 pCi/L MCL |
| Uranium | 1.7 µg/LMaximum | 2024 | Below 30 µg/L MCL |
City of Irving Water Utilities
2025 report; PFAS and lead samples from 2024
Irving’s PFAS averages include detected samples only. The report says over 98% of collected samples had no detectable PFAS and were excluded from those averages. Do not read these as the average concentration across all samples.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | Test at home No Irving hardness value verified here | 2025 report checked | Not confirmedWe do not substitute Dallas’ hardness number for Irving. A current hardness test can establish whether scale treatment belongs in your system. |
| Chloramine | 2.84 ppmAverage; range 0.54–3.98 | 2025 | Average below 4 ppm MRDL |
| TTHMs | 18 ppbReported average LRAA; range 16–24 | 2025 | Below 80 ppb MCL |
| HAA5 | 20 ppbReported average LRAA; range 13–27 | 2025 | Below 60 ppb MCL |
| Fluoride | 0.686 ppmDallas-supplied water maximum; average 0.627 | 2025 | Below 4 ppm MCL |
| Lead | 1 ppbIrving tap-sample 90th percentile; 0 sites over AL | 2024 | Below 15 ppb action level |
| PFAS — PFOA | 4–5 pptRange among detections; detected-only average 4 | 2024 | Some detections above 4 ppt EPA comparisonHistorical samples; not a current compliance determination. |
| Nitrate as nitrogen | 0.802 ppmDallas-supplied water maximum | 2025 | Below 10 ppm MCL |
| PFAS — PFOS | 4 pptDetected-only average and detected range | 2024 | At 4 ppt EPA comparisonNondetects excluded from the reported average. |
| PFAS — PFBS | 5 pptDetected-only average; range 4–6 | 2024 | No individual federal MCL for this compoundDo not compare this amount with the PFOA/PFOS limits. |
| Copper | 0.272 ppmIrving tap-sample 90th percentile | 2024 | Below 1.3 ppm action level |
| Barium | 0.038 ppmDallas-supplied water maximum | 2025 | Below 2 ppm MCL |
| E. coli | 0 positive samplesIrving distribution monitoring | 2025 | No positive samples reportedThis is historical utility monitoring, not a home test. |
City of Garland Water Utilities
2025 report; PFAS samples from 2024
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 96–200 mg/L as CaCO₃ · reported range | 2025 measured range; FAQ average is undated | Moderately hard to very hard5.6–11.7 gpg. Garland’s separate FAQ describes a typical average of 161 mg/L (9.4 gpg), classified as hard. |
| Chloramine | 2.48 ppmAverage; range 0.5–4.2 | 2025 | Average below 4 ppm MRDL |
| TTHMs | 72.3 ppbReported highest level; range 21.7–72.3 | 2025 | Below 80 ppb MCLThe report marks no violation; the MCL uses an annual averaging basis. |
| HAA5 | 35.7 ppbReported highest level; range 16.5–35.7 | 2025 | Below 60 ppb MCL |
| Fluoride | 0.492 ppmMaximum; range 0.352–0.492 | 2025 | Below 4 ppm MCL |
| Lead | 1.22 ppb90th percentile; 0 sites over action level | 2025 | Below 15 ppb action level |
| PFAS — PFBA | 8.9 pptAverage; range 6.5–12 (converted from µg/L) | 2024 | No individual federal MCL for this compoundDetected does not create a universal high/low PFAS score. |
| Nitrate as nitrogen | 0.866 ppmMaximum | 2025 | Below 10 ppm MCL |
| PFAS — PFBS | 4.75 pptAverage; range 3.8–5.7 (converted from µg/L) | 2024 | No individual federal MCL for this compound |
| PFAS — PFHxA | 4.975 pptAverage; range 3.4–7.5 (converted from µg/L) | 2024 | No individual federal MCL for this compound |
| PFAS — PFPeA | 5.525 pptAverage; range 3.7–8.6 (converted from µg/L) | 2024 | No individual federal MCL for this compound |
| Copper | 1.000 ppm90th percentile | 2025 | Below 1.3 ppm action level |
| Total dissolved solids | 455 ppmMaximum; range 182–455 | 2025 | Below 500 ppm aesthetic guideline |
| Arsenic | 1 ppbReported highest level | 2025 | Below 10 ppb MCL |
City of Grand Prairie
2025 report; 2024 PFAS/lead; 2022 hardness guidance
The 2024 lead 90th percentile was below the action level, but 3 of 50 sampled sites exceeded 15 ppb and one result reached 75.1 ppb. A low system percentile does not rule out a problem at an individual home.
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 170 ppm as CaCO₃ · 2022 guidance | 2022 utility report; older guidance | Hard — older utility figureApproximately 9.9 grains per gallon. This historical figure is not a 2025 measurement; confirm today’s hardness before selecting or programming a softener. |
| Chloramine | 2.95 ppmAverage; range 0.60–4.70 | 2025 | Average below 4 ppm MRDL |
| TTHMs | 44.7 ppbHighest locational annual average | 2025 | Below 80 ppb MCL |
| HAA5 | 30.3 ppbHighest locational annual average | 2025 | Below 60 ppb MCL |
| Fluoride | Varies by supplier Purchased-water tables; not one citywide tap value | 2025 report | No single citywide high/low valueSee the utility’s supplier tables; do not average different systems. |
| Lead | 1.2 ppb90th percentile; 3 of 50 sites over 15 ppb | 2024 | System percentile below AL; some taps aboveMaximum sample: 75.1 ppb. Check home plumbing and test your tap. |
| PFAS — PFOS | 20 pptReported average; range 4.1–82 | 2024 | Above 4 ppt EPA comparisonHistorical monitoring, not a current compliance determination. |
| Nitrate as nitrogen | 1.15 ppmMaximum; range 0.034–1.15 | 2025 | Below 10 ppm MCL |
| PFAS — PFOA | 4.5 pptReported average; range 4.1–4.9 | 2024 | Above 4 ppt EPA comparisonCheck current results and exact treatment claims. |
| PFAS — PFHxS | 3.3 pptReported average; detected range 3.3–3.3 | 2024 | Compound-specific review neededFederal PFAS rule changes are being considered; see EPA. |
| Copper | 0.253 ppm90th percentile; 0 sites over action level | 2024 | Below 1.3 ppm action level |
| Nitrite | 0.374 ppmReported maximum | 2024 | Below 1 ppm MCL |
Los Angeles Department of Water and Power (LADWP)
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 103–236 mg/L as CaCO₃Range of six source averages | 2025View source ↗ | Moderately hard to very hardSource averages ≈ 6.0–13.8 gpg. Full source range: 78–280 mg/L. Your blend can differ. |
| Disinfectant residual | 1.7 mg/LTotal chlorine · highest running annual average | 2025View source ↗ | Below 4 mg/L MRDLLADWP uses chloramines; this is total residual, not a free-chlorine-only reading. |
| TTHM | 33.8 ppbHighest locational running annual average | 2025View source ↗ | Below 80 ppb MCL |
| HAA5 | 13.4 ppbHighest locational running annual average | 2025View source ↗ | Below 60 ppb MCL |
| Fluoride | 0.7 mg/LCitywide average · range 0.2–0.8 | 2025View source ↗ | Below California 2 mg/L MCLDedicated fluoride treatment is a separate selection. |
| Lead | <5 ppb90th percentile · 105 sampled taps | 2023View source ↗ | Below 15 ppb action level3 of 105 sites exceeded 15 ppb. A low system percentile does not rule out lead at an individual home. |
| Arsenic | <2–3.3 ppbRange of source averages · overall range <2–7.0 | 2025View source ↗ | Below 10 ppb MCLThe legal limit differs from California’s 0.004 ppb health goal. |
| PFAS | Not detected Tested PFAS at distribution entry points | Dec 2023–Sep 2024View source ↗ | Below reporting limitsHistorical UCMR5 results are not a current home test or proof of zero PFAS. |
| Nitrate as nitrogen | <0.4 mg/L as NAll six source averages · highest reported sample 1.4 | 2025View source ↗ | Below 10 mg/L MCL |
| Copper | 529 ppb90th percentile · 105 sampled taps | 2023View source ↗ | Below 1,300 ppb action level0 of 105 sites exceeded the action level. |
| Total dissolved solids | 234–545 mg/LRange of source averages · full range 187–625 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic standard; TDS is not a hardness measurement. |
| Hardness — Los Angeles Aqueduct Filtration Plant | 103 mg/L as CaCO₃Source average · range 96–117 | 2025View source ↗ | Moderately hardCalculated average: 6.0 gpg. Use the report’s service-area map to understand your blend. |
| Hardness — Northern Combined Wells | 115 mg/L as CaCO₃Source average · range 78–151 | 2025View source ↗ | Moderately hardCalculated average: 6.7 gpg. Use the report’s service-area map to understand your blend. |
| Hardness — Southern Combined Wells | 116 mg/L as CaCO₃Source average · range 83–159 | 2025View source ↗ | Moderately hardCalculated average: 6.8 gpg. Use the report’s service-area map to understand your blend. |
| Hardness — MWD Weymouth Plant | 234 mg/L as CaCO₃Source average · range 189–280 | 2025View source ↗ | Very hardCalculated average: 13.7 gpg. Use the report’s service-area map to understand your blend. |
| Hardness — MWD Diemer Plant | 236 mg/L as CaCO₃Source average · range 191–280 | 2025View source ↗ | Very hardCalculated average: 13.8 gpg. Use the report’s service-area map to understand your blend. |
| Hardness — MWD Jensen Plant | 140 mg/L as CaCO₃Source average · range 137–142 | 2025View source ↗ | HardCalculated average: 8.2 gpg. Use the report’s service-area map to understand your blend. |
City of San Diego Public Utilities Department
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 237–243 mg/L as CaCO₃Range of three City plant averages | 2025View source ↗ | Very hard at City plantsPurchased treated water averages 145 mg/L (hard) and has a wider range. See each supply below. |
| Disinfectant residual | 1.75 mg/LChloramines · distribution average | 2025View source ↗ | Below 4 mg/L MRDLRange: ND–3.80 mg/L. Choose filtration with verified chloramine performance. |
| TTHM | 55 ppbMaximum locational running annual average | 2025View source ↗ | Below 80 ppb MCLIndividual samples are not the annual-average compliance result. |
| HAA5 | 15 ppbMaximum locational running annual average | 2025View source ↗ | Below 60 ppb MCLIndividual samples are not the annual-average compliance result. |
| Fluoride | 0.6–0.8 mg/LRange of final-water plant averages | 2025View source ↗ | Below California 2 mg/L MCLFull final-water range: 0.2–0.9 mg/L. Natural and final-water fluoride rows are not added together. |
| Lead | ND (<5) ppb90th percentile · 56 sampled taps | 2023View source ↗ | Below 15 ppb action level0 of 56 sites exceeded the action level. Your plumbing can affect your tap. |
| Arsenic | ND (<2) ppbSupplementary nondetect list | 2025View source ↗ | Below reporting limitNot detected is not zero; MCL 10 ppb differs from the 0.004 ppb health goal. |
| PFAS — PFBA | 5.4 pptAlvarado average · range ND–7.0 | 2025View source ↗ | Detected; no MCL listedOther plant averages were ND. Do not compare PFBA to PFOA/PFOS limits. |
| Nitrate as nitrogen | ND mg/L as NAll plant averages · largest sample 0.5 | 2025View source ↗ | Below 10 mg/L MCLND is below the reporting limit. |
| PFOA and PFOS | ND (<2) pptSupplementary nondetect list | 2025View source ↗ | Below reporting limitsDoes not erase the separate PFBA detection. |
| Hardness — Alvarado | 237 mg/L as CaCO₃Average · range 203–270 | 2025View source ↗ | very hardCalculated average: 13.8 gpg. |
| Hardness — Miramar | 242 mg/L as CaCO₃Average · range 200–285 | 2025View source ↗ | very hardCalculated average: 14.1 gpg. |
| Hardness — Otay | 243 mg/L as CaCO₃Average · range 201–271 | 2025View source ↗ | very hardCalculated average: 14.2 gpg. |
| Hardness — Purchased treated water | 145 mg/L as CaCO₃Average · range 54.4–232 | 2025View source ↗ | hard average; range spans soft through very hardCalculated average: 8.5 gpg. |
| TDS — Alvarado | 532 mg/LAverage · range 434–590 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; this does not measure hardness. |
| TDS — Miramar | 533 mg/LAverage · range 474–611 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; this does not measure hardness. |
| TDS — Otay | 585 mg/LAverage · range 508–634 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; this does not measure hardness. |
| TDS — Purchased treated water | 361 mg/LAverage · range 105–513 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; this does not measure hardness. |
Anaheim Public Utilities
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 235–316 mg/L as CaCO₃Range of three source averages | 2025View source ↗ | Very hard source averagesFull range: 162–431 mg/L. Source averages ≈ 13.7–18.5 gpg. |
| Disinfectant residual | 1.1 mg/LChlorine · reported average | 2025View source ↗ | Below 4 mg/L MRDLReported range: ND–3.9 mg/L. |
| TTHM | 77 ppbHighest locational running annual average | 2025View source ↗ | Close to 80 ppb MCLBelow the limit. A single-sample maximum of 93 ppb is not the annual-average compliance result. |
| HAA5 | 13 ppbHighest locational running annual average | 2025View source ↗ | Below 60 ppb MCLSee the missed-sample notice above. |
| Fluoride | 0.3–0.7 mg/LRange of source averages · full range 0.3–0.8 | 2025View source ↗ | Below California 2 mg/L MCL |
| Lead | ND (<5) ppb90th percentile · 51 sampled taps | 2025View source ↗ | Below 15 ppb action level0 of 51 sites exceeded the action level. ND is not zero. |
| Arsenic | ND–2.1 ppbRange of source averages · full range ND–2.5 | 2025View source ↗ | Below 10 ppb MCLDifferent from California’s 0.004 ppb health goal. |
| PFAS | Detected Multiple compounds in source-column results | 2025View source ↗ | Review compound-specific resultsThese are not individual home measurements. See PFOS/PFOA and other compounds below. |
| Nitrate as nitrogen | 2.6 / ND / ND mg/L as NGroundwater / Lenain / MWD averages · range ND–5.1 | 2025View source ↗ | Below 10 mg/L MCL |
| Copper | 0.1 mg/L90th percentile · 51 sampled taps | 2025View source ↗ | Below 1.3 mg/L action level |
| Total dissolved solids | 557 / 640 / 541 mg/LGroundwater / Lenain / MWD averages | 2025View source ↗ | Below 1,000 mg/L secondary MCLFull range: 338–784 mg/L. This is an aesthetic benchmark. |
| Hardness — Groundwater | 316 mg/L as CaCO₃Source average | 2025View source ↗ | Very hardCalculated average: 18.5 gpg. |
| Hardness — Lenain | 298 mg/L as CaCO₃Source average | 2025View source ↗ | Very hardCalculated average: 17.4 gpg. |
| Hardness — MWD | 235 mg/L as CaCO₃Source average | 2025View source ↗ | Very hardCalculated average: 13.7 gpg. |
| PFOS | 4.1 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–29 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFOA | 2.3 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–10 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFHxS | 2.1 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–13 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFBS | ND / ND / ND pptGroundwater / Lenain / MWD averages · range ND–3.4 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFBA | 4.9 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–17 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFHxA | 1.2 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–8.8 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
| PFPeA | 4.6 / ND / ND pptGroundwater / Lenain / MWD averages · range ND–13 | 2025View source ↗ | Detection reportedSource-column results. Report notification/response levels are not federal MCLs; these values do not establish a present compliance finding. |
Riverside Public Utilities
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 197 mg/L as CaCO₃average · range 180–210 | 2025View source ↗ | Very hard averageCalculated average: 11.5 gpg. USGS very hard: above 180 mg/L. |
| Chlorine | 0.58 mg/Laverage · range 0.25–0.85 | 2025View source ↗ | Below 4 mg/L MRDL |
| TTHM | 6.1 ppbhighest locational running annual average · range 1–7.6 | 2025View source ↗ | Below MCL 80 µg/L |
| HAA5 | Not listed ppbNot listed in the detected-results table | 2025 report reviewView source ↗ | Unknown; not zeroDo not infer ND or zero. |
| Fluoride | 0.45 mg/Laverage · range 0.39–0.53 | 2025View source ↗ | Below California 2 mg/L MCLNaturally occurring; utility says it does not plan artificial addition. |
| Nitrate as nitrogen | 5.4 mg/Laverage · range 4.7–6.5 | 2025View source ↗ | Below MCL and PHG 10 mg/L |
| Arsenic | 3.3 ppbaverage · range ND–4.6 | 2025View source ↗ | Below MCL 10 µg/L |
| Hexavalent chromium | 2.1 ppbaverage · range 2.0–2.2 | 2025View source ↗ | Below California MCL 10 µg/L |
| Perchlorate | 2.3 ppbaverage · range ND–3.2 | 2025View source ↗ | Below MCL 6 µg/L |
| Uranium | 6.1 pCi/Laverage · range 4.7–9.9 | 2025View source ↗ | Below MCL 20 pCi/L |
| Lead | ND ppb90th percentile; 51 household samples · range ND | 2025View source ↗ | Below 15 ppb action levelZero samples exceeded AL; individual homes can differ. |
| Copper | 0.47 mg/L90th percentile; 51 household samples · range ND–0.8 | 2025View source ↗ | Below 1.3 mg/L action levelZero samples exceeded AL. |
| Total dissolved solids | 357 mg/Laverage · range 320–380 | 2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; TDS is not hardness. |
| pH | 8 pH unitsaverage · range 7.4–8.1 | 2025View source ↗ | Descriptive water chemistry |
| PFHxA | 3.6 pptaverage · range ND–4.3 | 2023 UCMR5 data in 2025 reportView source ↗ | Historical PFAS result2023 UCMR5 data, not a 2025 measurement. Notification level 1000 ng/L |
| PFPeA | 6.3 pptaverage · range 5.6–8.7 | 2023 UCMR5 data in 2025 reportView source ↗ | Historical PFAS result2023 UCMR5 data, not a 2025 measurement. No standard listed |
| PFBA | ND pptaverage · range ND–5.6 | 2023 UCMR5 data in 2025 reportView source ↗ | Historical PFAS result2023 UCMR5 data, not a 2025 measurement. No standard listed |
| PFAS | Detected 2023 UCMR5 results | 2023View source ↗ | Review sampling scopeSee compound-specific results and dates in the expanded table. These are not home tests. |
San Bernardino Municipal Water Department
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 242.2 mg/L as CaCO₃average · range 130–330 | 2025View source ↗ | Very hard averageCalculated average: 14.1 gpg. USGS very hard: above 180 mg/L. |
| Chlorine | 0.74 mg/Laverage · range 0.20–3.2 | 2024View source ↗ | Below 4 mg/L MRDL2024 is the year printed in the 2025 report; do not silently change to 2025. |
| TTHM | 3.3 ppblocational running annual average · range ND–8.70 | 2025View source ↗ | Below MCL 80 µg/L |
| HAA5 | ND ppblocational running annual average · range ND–ND | 2025View source ↗ | Not detected; MCL 60 ppb |
| Fluoride | 0.41 mg/Laverage · range 0.24–1.10 | 2023View source ↗ | Below California 2 mg/L MCL |
| Nitrate as nitrogen | 3.74 mg/Laverage · range 0.0–7.5 | 2024–2025View source ↗ | Below MCL 10 mg/L |
| Nitrate as NO3 | 16.56 mg/Laverage · range ND–33.0 | 2023–2025View source ↗ | Below MCL 45 mg/LDo not mix with nitrate as nitrogen. |
| Arsenic | 2.38 ppbaverage · range ND–7.6 | 2023–2025View source ↗ | Below MCL 10 µg/LPHG column prints 7, inconsistent with known arsenic PHG; omit this apparent report error. |
| Perchlorate | 0.83 ppbaverage · range ND–2.7 | 2023–2025View source ↗ | Below MCL 6 µg/L |
| Hexavalent chromium | 1.25 ppbaverage · range ND–3.60 | 2023–2024View source ↗ | Review source and current standardOlder measurements. The source table’s “NS” is not presented as a current regulatory finding. |
| PCE | 0.16 ppbaverage · range ND–2.5 | 2023–2025View source ↗ | Below MCL 5 µg/L |
| TCE | 0.01 ppbaverage · range ND–0.65 | 2023–2025View source ↗ | Below MCL 5 µg/L |
| Lead | 1.9 ppb90th percentile; 53 household samples · range ND–81 | 2024View source ↗ | Below 15 ppb action levelOne customer-collected sample was 81 µg/L; eight follow-up samples were below AL, including ND at kitchen faucet. Report lists zero sites exceeding AL. Do not say every sample below AL or no lead detected. |
| Copper | 0.29 mg/L90th percentile; 53 samples · range 0.026–0.71 | 2024View source ↗ | Below 1.3 mg/L action level |
| Total dissolved solids | 344.88 mg/Laverage · range 200–440 | 2023–2025View source ↗ | Below 1,000 mg/L secondary MCLAesthetic benchmark; TDS is not hardness. |
| PFOA | 1.1 pptsource-monitoring average · range ND–5.7 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. Report column RL 10 ng/L; not MCL |
| PFOS | 0.7 pptsource-monitoring average · range ND–5.3 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. Report column RL 40 ng/L; not MCL |
| PFHxS | 2.2 pptsource-monitoring average · range ND–8.5 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. Report column RL 10 ng/L |
| PFPeA | 1.8 pptsource-monitoring average · range ND–6.4 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. |
| PFHpA | 0.4 pptsource-monitoring average · range ND–3.4 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. |
| PFHxA | 1.8 pptsource-monitoring average · range ND–6.4 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. Report column 1000 ng/L |
| PFBS | 2.8 pptsource-monitoring average · range ND–9.7 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. Report column 500 ng/L |
| PFBA | 1.2 pptsource-monitoring average · range ND–4.1 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. |
| PFDoDA | 0.02 pptsource-monitoring average · range ND–1.9 | 2025View source ↗ | Source-monitoring resultSource monitoring does not establish the result at a household tap. |
| PFAS | Detected 2025 source monitoring | 2025 source monitoringView source ↗ | Review sampling scopeSee compound-specific results and dates in the expanded table. These are not home tests. |
San Jose Water — main system
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 99–288 mg/L as CaCO₃range of three source averages | 2025View source ↗ | Moderately hard to very hardSource averages: Valley Water 99, mountain water 151, groundwater 288. Full reported range: 77–451. This is not a home measurement. |
| Total chlorine | 1.42 mg/Lrunning annual average | 2025View source ↗ | Below the 4 mg/L limitThe utility uses chlorine and chloramine. Ask for filtration suited to both disinfectants. |
| TTHMs | 47.7 µg/L (ppb)highest site average | 2025View source ↗ | Below the 80 ppb limitDisinfection byproduct result; compliance uses the prescribed site average, not an individual tap result. |
| HAA5 | 27.3 µg/L (ppb)highest site average | 2025View source ↗ | Below the 60 ppb limitHaloacetic acids are disinfection byproducts. The annual report gives the sampling context. |
| Fluoride | 0.75 mg/Ltreated Valley Water average | 2025View source ↗ | Below California’s 2 mg/L limitOther source averages differ: groundwater 0.10 mg/L; mountain source not detected. Standard filtration is not dedicated fluoride treatment. |
| Lead | 1.6–2.1 µg/L (ppb)fall / spring 90th percentiles | 2025View source ↗ | Below the report’s action levelOne sampled home in each round exceeded 15 ppb. A system percentile does not establish the lead level in your home. |
| Arsenic | ND–2.2 µg/L (ppb)groundwater sample range | 2025View source ↗ | Below the 10 ppb limitGroundwater average was not detected. ND means below the reporting threshold, not zero. |
| PFAS | Detected source monitoringincludes offline wells | 2025View source ↗ | Source context mattersThe report includes wells that were not supplying customers. These detections are not a measurement of water at your tap. |
| Hardness — mountain source | 151 mg/L as CaCO₃source average | 2025View source ↗ | HardAbout 8.8 grains per gallon, calculated using mg/L ÷ 17.1. |
| Hardness — groundwater | 288 mg/L as CaCO₃average; range 175–451 | 2025View source ↗ | Very hard averageAbout 16.8 grains per gallon. Supports a softener recommendation when this supply serves the home. |
| Hardness — Valley Water | 99 mg/L as CaCO₃average; range 77–146 | 2025View source ↗ | Moderately hard averageAbout 5.8 grains per gallon; the upper end reaches the hard category. |
| Chromium-6 — groundwater | 4.67 µg/Laverage; range 0.74–8.54 | 2025View source ↗ | Below the 10 µg/L limitThe report’s health goal is 0.02 µg/L; a health goal differs from an enforceable MCL. |
| Nitrate as nitrogen — groundwater | 3.1 mg/Laverage; range 0.61–6.5 | 2025View source ↗ | Below the 10 mg/L limitNitrate treatment needs a verified treatment claim; a softener is not nitrate treatment. |
| Bromate — Valley Water | 1.5 µg/Laverage; range ND–5.4 | 2025View source ↗ | Below the 10 µg/L limitResult applies to the treated Valley Water source. |
| Total dissolved solids | 200 / 397 / 247 mg/Lmountain / groundwater / Valley averages | 2025View source ↗ | Below report’s 1,000 mg/L secondary limitTDS is not a measurement of any one contaminant. |
| PFHxS — groundwater | ND–9.8 ng/L (ppt)source range; includes offline wells | 2025View source ↗ | Some samples above the 3 ppt notification levelIncludes wells not supplying customers. A notification level is not an MCL. |
| PFOA — groundwater | ND–4.6 ng/L (ppt)source range; includes offline wells | 2025View source ↗ | Some samples above the 4 ppt notification levelDo not interpret the maximum as a home’s exposure. |
| PFOS — groundwater | ND–9.7 ng/L (ppt)source range; includes offline wells | 2025View source ↗ | Some samples above the 4 ppt notification levelAsk the utility about the current source blend and treatment; check exact model reduction claims. |
East Bay Municipal Utility District (EBMUD)
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 14–160 mg/L as CaCO₃range across treatment plants | 2025View source ↗ | Soft to hard, depending on supplyWalnut Creek, Lafayette and Orinda ranges are soft; Sobrante is moderately hard; Upper San Leandro is hard. |
| Chloramine | 2.4 mg/L as chlorinehighest running annual average | 2025View source ↗ | Below the 4 mg/L limitIndividual samples ranged 0.07–3.71 mg/L. Select treatment with a verified chloramine claim. |
| TTHMs | 57 µg/L (ppb)highest locational annual average | 2025View source ↗ | Below the 80 ppb limitSome individual samples reached 110 ppb. The compliance comparison uses locational running annual averages. |
| HAA5 | 50 µg/L (ppb)highest locational annual average | 2025View source ↗ | Below the 60 ppb limitIndividual samples reached 76 ppb. An individual sample and an annual average are different measures. |
| Fluoride | 0.7 mg/Lsystem average; samples 0.6–0.8 | 2025View source ↗ | Below California’s 2 mg/L limitFluoride requires dedicated treatment if reducing it is a goal. |
| Lead | ND 90th percentile53 sampled homes | 2024View source ↗ | Below the report’s action levelNo samples exceeded 15 ppb; reported range ND–13.3 ppb. Home plumbing can change tap results. |
| Arsenic | Not listed in the selected report tablesno numeric result shown | 2025 reportView source ↗ | Unknown, not zeroThe absence of a value in these detected-contaminant tables does not establish your home’s arsenic level. |
| PFAS | Detected selected individual samplesPFHxA and PFBA in UCMR5 table | 2025 reportView source ↗ | Compound-specific findingsSelected plant samples contained PFHxA or PFBA even though the table’s system averages were ND. See the full report for context. |
| Hardness — Walnut Creek | 15–21 mg/L as CaCO₃plant sample range | 2025View source ↗ | SoftPlant-associated samples may include water from another plant; confirm your current blend. |
| Hardness — Lafayette | 14–27 mg/L as CaCO₃plant sample range | 2025View source ↗ | SoftPlant-associated samples may include water from another plant; confirm your current blend. |
| Hardness — Orinda | 14–40 mg/L as CaCO₃plant sample range | 2025View source ↗ | SoftPlant-associated samples may include water from another plant; confirm your current blend. |
| Hardness — Sobrante | 64–98 mg/L as CaCO₃plant sample range | 2025View source ↗ | Moderately hardPlant-associated samples may include water from another plant; confirm your current blend. |
| Hardness — Upper San Leandro | 140–160 mg/L as CaCO₃plant sample range | 2025View source ↗ | HardPlant-associated samples may include water from another plant; confirm your current blend. |
| PFHxA — Upper San Leandro | ND–3.4 ng/L (ppt)individual sample range | 2025 reportView source ↗ | Below report’s 1,000 ppt notification levelUCMR5 result; the notification level is not an MCL. |
| PFBA — Upper San Leandro | ND–5.2 ng/L (ppt)individual sample range | 2025 reportView source ↗ | No benchmark listed in this tableSobrante range was ND–5.1 ppt; other listed plants were ND. |
| Chlorate | 108 µg/L (ppb)system average | 2025View source ↗ | Below report’s 800 ppb notification levelA notification level is not an enforceable MCL. |
| NDMA | 3.9 ng/L (ppt)highest locational annual average | 2025View source ↗ | Below report’s 10 ppt notification levelHighest individual sample in the table was 6.5 ppt. |
| Total dissolved solids | 65 mg/Lsystem average | 2025View source ↗ | Below the 500 mg/L secondary limitTDS describes dissolved material collectively; it is not a contaminant-specific test. |
City of Sacramento Department of Utilities
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 83 mg/L as CaCO₃reported system average | 2023–2025View source ↗ | Moderately hardAbout 4.9 gpg. Source figures differ: Fairbairn 34, Sacramento River plant 63, groundwater range 15–154 mg/L. |
| Chlorine | 0.8 mg/Lsystem average; range 0.2–1.4 | 2025View source ↗ | Below the 4 mg/L limitThis is a disinfectant residual in utility monitoring, not a tap-specific measurement. |
| TTHMs | 63 µg/L (ppb)reported system average | 2025View source ↗ | Reported value below 80 ppbThe table labels this a system average. A home’s sample may differ; compliance uses the required averaging method. |
| HAA5 | 29 µg/L (ppb)system average; range ND–31 | 2025View source ↗ | Reported value below 60 ppbDisinfection byproducts; keep the result’s averaging basis with its benchmark. |
| Fluoride | 0.7 mg/Lsystem average; range 0.2–1.0 | 2025View source ↗ | Below California’s 2 mg/L limitDedicated fluoride treatment is different from standard whole-house filtration. |
| Lead | ND 90th percentile56 sampled homes | 2023View source ↗ | Below the report’s action levelNo sampled homes exceeded the report’s 15 ppb action level. These samples were collected in 2023. |
| Arsenic | ND–4.3 µg/L (ppb)groundwater sample range | 2023–2025View source ↗ | Below the 10 ppb limitThe system average was reported as ND. A groundwater range is not the value at your home. |
| PFAS | No numeric value in this report’s PFAS sectionmonitoring discussed; see utility updates | 2025 reportView source ↗ | Unknown from this tableDo not read missing numbers as zero PFAS. Request current source-specific results from the city. |
| Hardness — Fairbairn plant | 34 mg/L as CaCO₃reported source value | 2023–2025View source ↗ | SoftAmerican River treatment plant; not a county average. |
| Hardness — Sacramento River plant | 63 mg/L as CaCO₃reported source value | 2023–2025View source ↗ | Moderately hardSource result; the blend at a home may differ. |
| Hardness — groundwater | 15–154 mg/L as CaCO₃source range | 2023–2025View source ↗ | Soft to hardConfirm tap hardness when selecting softener size and settings. |
| Chromium-6 | 3.50 µg/Lsystem average; groundwater ND–7.0 | 2023–2025View source ↗ | Below the 10 µg/L limitThe report lists a 0.02 µg/L health goal, which is different from the MCL. |
| Nitrate as nitrogen | 1.0 mg/Lsystem average; groundwater ND–3.0 | 2025View source ↗ | Below the 10 mg/L limitDo not assume standard filtration or a softener treats nitrate. |
| Copper | 0.06 mg/L90th percentile | 2023View source ↗ | Below the 1.3 mg/L action levelNone of the 56 sampled homes exceeded the action level. |
| Total dissolved solids | 205 mg/Lsystem average | 2023–2025View source ↗ | Below report’s 1,000 mg/L secondary limitSource values vary: 47 and 110 mg/L at river plants; groundwater 180–280. |
| Sodium | 26 mg/Lsystem average | 2023–2025View source ↗ | No MCL listed in this tableSodium and hardness are separate measurements. |
Contra Costa Water District (CCWD)
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 74 mg/L as CaCO₃average at both treatment plants | 2025View source ↗ | Moderately hardAbout 4.3 gpg. Plant ranges span 54–96 mg/L, from soft to moderately hard. |
| Chloramine | 2.1 mg/L as chlorinesystem average; range ND–3.4 | 2025View source ↗ | Below the 4 mg/L limitChoose a filter with a verified chloramine reduction claim at the required flow. |
| TTHMs | 28 µg/L (ppb)system average; range 13–33 | 2025View source ↗ | Reported value below 80 ppbThe report’s compliance method and a home’s individual sample are different measures. |
| HAA5 | 16 µg/L (ppb)system average; range 4.4–21 | 2025View source ↗ | Reported value below 60 ppbHaloacetic acids are disinfection byproducts. |
| Fluoride | 0.7 mg/Lsystem average; range 0.6–0.9 | 2025View source ↗ | Below California’s 2 mg/L limitFluoride reduction needs an appropriate dedicated treatment stage. |
| Lead | ND 90th percentile64 sampled homes | June 2025View source ↗ | Below action level; one high sampleOne of 64 homes exceeded 15 ppb. The system percentile is not a guarantee for an individual tap. |
| Arsenic | Not listed in the selected report tablesno numeric result shown | 2025 reportView source ↗ | Unknown, not zeroAsk the utility for the relevant monitoring result if arsenic is a specific concern. |
| PFAS | Not detected utility’s drinking-water statementno compound-level values shown here | 2025 reportView source ↗ | Non-detect does not mean zeroCCWD reports no detection in its drinking water. Check its detailed PFAS results for compounds and reporting limits. |
| Hardness — Bollman plant | 74 mg/L as CaCO₃average; range 59–90 | 2025View source ↗ | Moderately hard averageBollman is the district’s Concord treatment plant. |
| Hardness — Randall-Bold plant | 74 mg/L as CaCO₃average; range 54–96 | 2025View source ↗ | Moderately hard averageThe plant’s range crosses the soft/moderately hard boundary. |
| Copper | 0.11 mg/L90th percentile | June 2025View source ↗ | Below the 1.3 mg/L action levelNone of 64 homes exceeded the action level. |
| TDS — Bollman / Randall-Bold | 212 / 199 mg/Lplant averages | 2025View source ↗ | Below the 500 mg/L secondary limitFull sample ranges were 159–281 and 137–301 mg/L. |
| Chloride — Bollman / Randall-Bold | 45 / 46 mg/Lplant averages | 2025View source ↗ | Below the 250 mg/L secondary limitThis is chloride, not the disinfectant chlorine. |
| Sulfate — Bollman / Randall-Bold | 58 / 48 mg/Lplant averages | 2025View source ↗ | Below the 250 mg/L secondary limitSulfate and sulfur odors are not interchangeable measurements. |
| Sodium — Bollman / Randall-Bold | 47 / 43 mg/Lplant averages | 2025View source ↗ | No MCL listed in this tableA softener does not remove sodium. |
City of Fresno Water Division
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 129 mg/L as CaCO₃average; range 87–150 | 2025View source ↗ | Hard averageAbout 7.5 gpg. The reported range includes moderately hard and hard water; confirm your home’s current level. |
| Chlorine | 1.45 mg/Laverage; range 0.02–1.85 | 2025View source ↗ | Below the 4 mg/L limitListed as chlorine (NaOCl) in the utility report. Select filtration for the disinfectant and desired flow. |
| TTHMs | 0.18 µg/L (ppb)reported average; range ND–4.3 | 2025View source ↗ | Reported value below 80 ppbThis average is transcribed from the report; it is not a household measurement. |
| HAA5 | 4.30 µg/L (ppb)reported average; range ND–9.7 | 2025View source ↗ | Reported value below 60 ppbDisinfection byproducts; use the report’s averaging and sampling context. |
| Fluoride | 0.12 mg/Laverage; range 0.10–0.13 | 2025View source ↗ | Below California’s 2 mg/L limitA low reported result is not zero; fluoride reduction requires dedicated treatment. |
| Lead | ND 90th percentile53 sampled homes | August 2025View source ↗ | Below the report’s action levelNo samples exceeded 15 ppb. A current tap test is needed to assess your own plumbing. |
| Arsenic | 3.15 µg/L (ppb)average; range ND–5.1 | 2025View source ↗ | Below the 10 ppb limitThe report’s 0.004 ppb health goal is much lower than the legal limit. Below MCL does not mean zero. |
| PFAS | Detected source-well monitoringsome affected wells removed from service | 2025View source ↗ | Some source results above notification levelsPFOA, PFOS and PFHxS were detected. Use the detailed utility results and current supply information before selecting treatment. |
| Nitrate as nitrogen | 4.80 mg/Laverage; reported range ND–12 | 2025View source ↗ | Average below 10; high sample investigatedThe utility attributes the high Well 85 result to lab error after confirmation testing. Do not present 12 mg/L as a confirmed citywide level. |
| Chromium-6 | 2.50 µg/Laverage; range 0.1–9.6 | 2025View source ↗ | Below the 10 µg/L limitThe report’s 0.02 µg/L health goal is different from the MCL. |
| Copper | 0.18 mg/L90th percentile | August 2025View source ↗ | Below the 1.3 mg/L action levelNo sampled homes exceeded the action level. |
| Tetrachloroethylene (PCE) | 0.07 µg/Laverage; range ND–1.9 | 2025View source ↗ | Below the 5 µg/L limitTreatment claims must name the exact contaminant and model. |
| Trichloroethylene (TCE) | 0.32 µg/Laverage; range ND–2.3 | 2025View source ↗ | Below the 5 µg/L limitA system average cannot identify the value at a particular home. |
| PFOA | 1.33 ng/L (ppt)average; source range ND–13 | 2025View source ↗ | Some samples above the report’s 4 ppt notification levelThe report describes affected wells removed from service. Notification levels are not MCLs. |
| PFOS | 1.58 ng/L (ppt)average; source range ND–24 | 2025View source ↗ | Some samples above the report’s 4 ppt notification levelThese source-well maxima do not establish a tap concentration. |
| PFHxS | 0.91 ng/L (ppt)average; source range ND–38 | 2025View source ↗ | Some samples above the report’s 3 ppt notification levelThe report includes well shutdowns; confirm current supply and compound-specific treatment. |
| PFBS | 0.46 ng/L (ppt)average; source range ND–7 | 2025View source ↗ | Below the report’s 500 ppt notification levelNotification levels and federal MCLs are different types of benchmarks. |
| Total dissolved solids | 186.8 mg/Laverage; range 87–260 | 2025View source ↗ | Below report’s 1,000 mg/L secondary limitTDS does not establish whether a specific contaminant is present. |
City of Atlanta Department of Watershed Management
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 30 mg/L as CaCO₃MyTapWater estimates 1.8 gpg for Fulton County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Chlorine | 1.13 mg/LHighest monthly average; range <0.07–1.90. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.74 mg/LHighest monthly average; range 0.46–0.83. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 70.5 µg/LHighest quarterly locational running annual average; range 18.0–71.4. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 35.5 µg/LHighest quarterly locational running annual average; range 15.2–37.3. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.72 mg/LMeasured together as nitrogen; annual average, range 0.56–0.82. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 1.4 µg/L90th percentile at sampled taps; range 0–10.0. | 2024View source ↗ | Below 15 µg/L action levelAL in the utility report: 15 µg/L. |
| Turbidity | 0.09 NTUHighest monthly average; range 0.01–0.31. | 2025View source ↗ | Treatment target met100% of samples met the report’s 0.3 NTU criterion. |
| Copper | 0.14 mg/L90th percentile at sampled taps; range 0.0011–0.4. | 2024View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
Fulton County Public Works — North Fulton
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 30 mg/L as CaCO₃MyTapWater estimates 1.8 gpg for Fulton County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Chlorine | 1.99 mg/LHighest detected residual; range <0.04–1.99. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.80 mg/LHighest plant result; range 0.61–0.80. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 59.1 µg/LHighest reported running average; sample range 21.2–74.96. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 35.3 µg/LHighest reported running average; range 3.3–42.0. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate | 0.56 mg/LPlant result; no sample range given. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 1.6 µg/L90th percentile; none of 50 taps exceeded the stated action level. | 2024View source ↗ | Below 15 µg/L action levelAL in the utility report: 15 µg/L. |
| Copper | 190 µg/L90th percentile; none of 50 taps exceeded the stated action level. | 2024View source ↗ | Below 1300 µg/L action levelAL in the utility report: 1300 µg/L. |
Gwinnett County Department of Water Resources
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 1.34 gpgUtility mineral table: range 1.05–1.87 gpg; average ≈23 mg/L as CaCO₃. | Utility brewing-water table · sample year not statedView source ↗ | Soft utility average |
| Chlorine | 1.43 mg/LUtility average; range 0.00–2.64. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.83 mg/LUtility average; range 0.40–1.01. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 72.8 µg/LHighest reported locational running annual average; table range 13.5–72.8. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 29.6 µg/LHighest reported locational running annual average; table range 12.0–29.6. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.82 mg/LAverage; nitrate and nitrite combined, range 0.78–0.86. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 0 of 50 sites above action levelPrior tap round; the utility table lists zero sites over its lead action level. | 2023View source ↗ | No sampled sites over levelThis site count does not establish the concentration in an individual home. |
| Turbidity | 0.16 NTUHighest turbidity detected. | 2025View source ↗ | Treatment target metThe report says 100% of samples were below 0.3 NTU. |
| Copper | 0.18 mg/L90th-percentile tap result. The report’s site count and listed range do not agree; ask the utility about individual samples. | 2023View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
Cobb County Water System
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 31.7 / 35.1 mg/LQuarles average: 31.7 mg/L; Wyckoff average: 35.1 mg/L. These wholesale plant averages are about 1.9 and 2.1 gpg. | 2025 · wholesaler plant averagesView source ↗ | Soft at both plants |
| Free chlorine | 2.00 mg/LReported residual; range 0.00–2.00. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.95 mg/LHighest result; range 0.54–0.95. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 60 µg/LHighest locational running annual average, site 513; samples 11.92–80.9. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 37 µg/LHighest locational running annual average, site 504; samples 8.57–47.1. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.79 mg/LHighest result; measured together as nitrogen, range 0.26–0.79. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 2.9 µg/L90th percentile; two samples over the action level, range 0–37. | 2025View source ↗ | Below 15 µg/L action levelAL in the utility report: 15 µg/L. |
| Turbidity | 0.12 NTUPlant-level result at the supplier’s treatment plants. | 2025View source ↗ | Treatment target met100% of samples were below 0.3 NTU in the report. |
| Copper | 0.078 mg/L90th percentile; range 0.0038–0.47; no samples exceeded the action level. | 2025View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
| Chlorite | 0.24 mg/LReported result; range 0.013–0.24. | 2025View source ↗ | Below 1 mg/L limitMCL in the utility report: 1 mg/L. |
DeKalb County Department of Watershed Management
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 29 mg/L as CaCO₃MyTapWater estimates 1.7 gpg for Dekalb County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Free chlorine | 1.70 mg/LAnnual average; range 1.63–1.77. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.8 mg/LAnnual average; range 0.5–1.5. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 28 µg/LAnnual average as defined in the county table; range 15.7–50.9. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 9.0 µg/LAnnual average; range 4.9–19.2. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate as nitrogen | 0.8 mg/LAnnual average; range 0.6–0.8. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 5.6 µg/L90th percentile; sample range 0–930 µg/L. | 2025View source ↗ | One tap above action levelThe system percentile was below the report’s 15 µg/L action level. A home result can differ markedly. |
| Turbidity | 0.20 NTUHighest detected turbidity. | 2025View source ↗ | Below 1 NTU ceilingThe accompanying monthly percentage is 99.00% below 0.3 NTU. |
| Copper | 0.02 mg/L90th percentile; range 0.000–0.038; no taps over the action level. | 2025View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
City of Savannah — Main System
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 87 mg/L as CaCO₃MyTapWater estimates 5.1 gpg for Chatham County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Moderately hard regional estimate |
| Chlorine | 2.20 mg/LThe city lists 2.20 ppm as detected but 0.01–1.20 ppm as the range. | 2025View source ↗ | Check conflicting rangeThe listed residual limit is 4 mg/L. Ask Savannah to clarify the discrepancy. |
| Fluoride | 1.26 mg/LReported detection; range 0.05–1.26. | 2023View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | Verify with utility The online TTHM row displays percent removal, not a TTHM concentration. | 2026 report · 2025 dataView source ↗ | No numeric ratingA percentage cannot be compared with a TTHM limit in µg/L. The I&D figure belongs to a different system. |
| Haloacetic acids (HAA5) | 41.025 µg/LCity table’s reported result; individual samples nondetect–76. | 2025View source ↗ | Below 60 µg/L limitThe listed limit is 60 µg/L and uses an annual-average basis. Individual samples are not compliance averages. |
| Arsenic | 6 µg/LReported detection; range nondetect–6. | 2023View source ↗ | Below 10 µg/L limitMCL in the utility report: 10 µg/L. |
| Lead | 3.9 µg/L90th percentile; sampled taps ranged from 0 to 100 µg/L. | 2024View source ↗ | One tap above action levelThe 90th percentile is below the report’s 15 µg/L action level. This is not a household lead test. |
| Turbidity | 99.34 % below 0.3 NTUPercentage of samples meeting the clarity threshold. | 2025View source ↗ | Above 95% minimumThe utility lists a 95% treatment-technique criterion. |
| Copper | 0.11 mg/L90th-percentile tap value; range 0.014–0.22. | 2024View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
City of Savannah — Industrial & Domestic (I&D)
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 87 mg/L as CaCO₃MyTapWater estimates 5.1 gpg for Chatham County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Moderately hard regional estimate |
| Chloramine | 2.02 mg/LThe I&D table lists both chlorine and chloramine. Chloramine range 0–2.02. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | Not listed No fluoride concentration is displayed in the I&D regulated-results table. | 2026 reportView source ↗ | No comparisonAn unlisted result is not a zero; ask the utility if fluoride reduction is a goal. |
| Total trihalomethanes (TTHM) | 66.95 µg/LCity’s reported value; published sample range 28.7–63.3. The summary and range have different bases or need clarification. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 41.025 µg/LReported result; published sample range 11.9–39. Do not treat the result as a sample maximum. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Chlorine | 2.20 mg/LI&D residual; range 0.01–2.20. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Lead | 6.4 µg/L90th-percentile tap result. | 2023View source ↗ | Below 15 µg/L action levelAL in the utility report: 15 µg/L. |
| Turbidity | About 2.0 NTUFiltered-water samples at the I&D plant on May 15–16. | May 2025View source ↗ | Treatment violation reportedSee the city’s incident notice for the cause and response. This is an event reading, not the annual average. |
| Copper | 0.410 mg/L90th-percentile tap result. | 2023View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
Cherokee County Water and Sewerage Authority — Main System
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 16 mg/L as CaCO₃CCWSA’s separate hardness guidance gives 16 mg/L, about 0.9 gpg. It does not identify a sampling year. | Undated utility hardness guidanceView source ↗ | Soft · utility guidance |
| Chlorine | 1.24 mg/LReported amount; range 0.2–1.9. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.64 mg/LReported amount; range 0.59–0.75. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 38.4 µg/LReported result; range 13.4–71.09. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 30.0 µg/LReported result; range 19.9–50.0. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.31 mg/LNitrate and nitrite combined; no range listed. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 0–220 µg/LRange across tap samples, not a 90th-percentile value. | 2024View source ↗ | One site over action levelOne of 51 sites exceeded 15 µg/L; see the utility’s retesting footnote. |
| Turbidity | 0.09 NTUReported amount; range 0.03–0.29. | 2025View source ↗ | Treatment target metThe utility says 100% of samples met its 0.30 NTU standard. |
| Copper | 0.9–2,300 µg/LRange across tap samples. | 2024View source ↗ | One site over action levelThe stated action level is 1,300 µg/L; see the 51-site sampling footnote. |
Clayton County Water Authority
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 34 mg/L as CaCO₃MyTapWater estimates 2.0 gpg for Clayton County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Chlorine | 0.97 mg/LReported amount; range 0.01–1.99. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.71 mg/LReported amount; range 0.00–1.26. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 69.8 µg/LReported rolling-average value; individual samples 22.1–83.8. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 47.3 µg/LReported rolling-average value; samples 16.2–60.0. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate | 0.74 mg/LReported amount; range 0.00–0.74. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 0 samples over action levelThe tap table shows zero samples above the report’s lead action level. | 2026 report · tap-sampling tableView source ↗ | No sampled sites over levelThe report uses 15 µg/L for its system assessment. A tap with lead plumbing needs its own test. |
| Turbidity | 0.407 NTUHighest value of the year. | 2025View source ↗ | Treatment target met99.99% of samples were below 0.3 NTU. |
| Chlorite | 0.41 mg/LReported amount; range 0.13–0.81. | 2025View source ↗ | Below 1 mg/L limitMCL in the utility report: 1 mg/L. |
| Chlorine dioxide | 0.12 mg/LReported residual; range 0.00–0.69. | 2025View source ↗ | Below 0.8 mg/L disinfectant limitMRDL in the utility report: 0.8 mg/L. |
Forsyth County Department of Water & Sewer
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 12 mg/L as CaCO₃MyTapWater estimates 0.7 gpg for Forsyth County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Free chlorine | 1.91 mg/LAverage; range 1.32–2.37. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.71 mg/LAverage; range 0.27–1.1. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 31.98 µg/LAverage in the county table; sample range 1.9–69.95. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 26.35 µg/LAverage in the county table; sample range 4.6–43.0. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.35 mg/LAverage; reported range 0.35–0.35. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 1 µg/L90th percentile; tap samples ranged from 0 to 49. | 2024View source ↗ | Below 15 µg/L action levelAL in the utility report: 15 µg/L. |
| Turbidity | 99 % at or below 0.3 NTUTurbidity range 0.07–0.70 NTU. | 2025View source ↗ | Above 95% minimumThe report’s treatment-technique criterion is ≥95% at or below 0.3 NTU. |
| Copper | 0.15 mg/L90th percentile; sample range 0.0037–0.35. | 2024View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
Henry County Water Authority
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 33 mg/L as CaCO₃MyTapWater estimates 1.9 gpg for Henry County from USGS data. This is regional context, not measured hardness for this utility or your tap. | Regional estimate · sample year not identifiedView source ↗ | Soft regional estimate |
| Chlorine | 2.36 mg/LReported residual; range 0.05–3.00. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.72 mg/LReported amount; range 0.15–0.98. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 66.4 µg/LFour-quarter result; sample range 16.6–81.4. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 38.1 µg/LFour-quarter result; sample range 13.5–47.2. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Organic carbon removal | 1.2 ratioReported treatment ratio; range 1.0–1.5. | 2025View source ↗ | Above minimum ratioThe utility explains a ratio of at least 1 is required. |
| Lead | 0 samples over action levelTap table: none over 15 µg/L; reported lead amount 1 µg/L. | 2026 report · tap-sampling tableView source ↗ | No sampled sites over levelA system sampling result does not establish lead at your particular tap. |
| Turbidity | 0.25 NTUHighest value of the year. | 2025View source ↗ | Treatment target met100% of measured samples were below 0.3 NTU. |
| Copper | 0.2 mg/LTap table: reported amount; zero samples above the stated action level. | 2026 report · tap-sampling tableView source ↗ | Below listed action levelThe report lists 1.3 mg/L as the system action level. |
City of Gainesville Department of Water Resources
| What was measured | Reported amount | Sample year / source date | How to read it |
|---|---|---|---|
| Hardness | 21.2 mg/LGainesville lists 21.2 mg/L in its annual-average mineral table, equivalent to about 1.2 gpg. | 2025 · annual averageView source ↗ | Soft annual average |
| Chlorine | 1.41 mg/LReported residual; range 0.0–2.20. | 2025View source ↗ | Below 4 mg/L disinfectant limitMRDL in the utility report: 4 mg/L. |
| Fluoride | 0.70 mg/LReported detected level; range 0.05–0.90. The report separately gives 0.53 ppm as average fluoride added. | 2025View source ↗ | Below 4 mg/L limitMCL in the utility report: 4 mg/L. |
| Total trihalomethanes (TTHM) | 26.53 µg/LHighest locational running annual average; table range 20.7–29.1. | 2025View source ↗ | Below 80 µg/L limitMCL in the utility report: 80 µg/L. |
| Haloacetic acids (HAA5) | 18.4 µg/LHighest locational running annual average; table range 15.5–20.1. | 2025View source ↗ | Below 60 µg/L limitMCL in the utility report: 60 µg/L. |
| Nitrate/nitrite | 0.4245 mg/LReported result; range 0.292–0.557. | 2025View source ↗ | Below 10 mg/L limitMCL in the utility report: 10 mg/L. |
| Lead | 0.34 µg/L90th percentile; no taps over the action level used in this report. | Fall 2024View source ↗ | Below 10 µg/L action levelAL in the utility report: 10 µg/L. |
| Turbidity | 0.30 NTUHighest value reported. | 2025View source ↗ | Below 1 NTU ceilingThe utility reports meeting its treatment-technique requirement. |
| Copper | 0.045 mg/L90th percentile; no taps over the action level. | Fall 2024View source ↗ | Below 1.3 mg/L action levelAL in the utility report: 1.3 mg/L. |
| Chlorite | 0.083 mg/LReported level; range 0.02–0.38. | 2025View source ↗ | Below 1 mg/L limitMCL in the utility report: 1 mg/L. |
Selected published results. A detection is not, by itself, a determination that water is unsafe.
Open the detailed local water report →Report dates & sourcesUtility reports and published guidance
Measurements and testing dates vary by utility. A ZIP code alone does not confirm your supplier.