Whole-home water. Your plumber. Your terms.
Store preview · Utility report pilot · Proposed pricing
2025 utility reports

What’s in Pasco County’s water?

Start with your water system, then look at the numbers.

This page summarizes the Pasco County Regional Water System, PWS 651-1361. Its 2025 report contains both local system data and separate Tampa Bay Water supply data. Other Pasco systems have their own reports in the county directory. Source

Confirm your supplier

Choose the report for your utility

The Regional Water System reports receiving about 95% of its drinking water from Tampa Bay Water. Its supply combines groundwater, surface water and desalinated water. Pasco’s directory lists separate reports for systems including Lake Jovita, Blanton Lakes and Southeast No. 2.

Match the utility and system on your water bill. A ZIP code or mailing address does not establish service boundaries.

PFAS values below are explicitly tied to a Tampa Bay Water sampling point. The report also records a supplier foaming-agents secondary-standard violation. Neither establishes the result at a particular Pasco home. Source
THE NUMBERS, WITH CONTEXT

What the reports measured

Browse the selected results by utility. These are substances and indicators—not a count of hazards in your home. Open the linked reports for the complete utility records.

How to read this table

ppm = mg/L; ppb = µg/L; ppt = ng/L. ND means below detection, not zero. MCL and MRDL are regulatory benchmarks reported in the source; action levels trigger system action. Annual averages, individual samples and household-tap percentiles are different measures. Compare like with like.

Sample years stay attached to each result. These historical reports do not replace current utility notices or a test of your tap.

20 report entries

01Pasco County Regional · PWS 651-1361Reported results, sample dates and source links14
Pasco County Regional · PWS 651-1361
Substance / indicatorReported resultBenchmark in sourceSample year / source
Chlorine and chloramines3.44 ppmHighest running annual averageIndividual range: 0.6–5.8 ppmMRDL 4 ppm2025 Source
TTHM21.2 ppbHighest locational running annual averageIndividual range: 3.5–39.4 ppbMCL 80 ppb2025 Source
HAA511.7 ppbHighest locational running annual averageIndividual range: 0.3–11.3 ppbMCL 60 ppb2025 Source
Alpha emitters2.98 pCi/LHighest reported resultIndividual range: ND–2.98 pCi/LMCL 15 pCi/L2023 Source
Combined radium1.713 pCi/LHighest reported resultIndividual range: ND–1.713 pCi/LMCL 5 pCi/L2023 Source
Uranium1.41 µg/LHighest reported resultIndividual range: ND–1.41 µg/LMCL 30 µg/L2023 Source
Arsenic1.2 ppbHighest reported resultIndividual range: ND–1.2 ppbMCL 10 ppb2023 Source
Barium0.016 ppmHighest reported resultIndividual range: 0.005–0.016 ppmMCL 2 ppm2023 Source
Fluoride0.28 ppmHighest reported resultIndividual range: 0.061–0.28 ppmMCL 4 ppm2023 Source
Nitrate · as nitrogen1.45 ppmJanuary sampleIndividual range: ND–1.45 ppmMCL 10 ppm2025 Source
Nitrite · as nitrogen0.020 ppmJanuary sampleIndividual range: ND–0.020 ppmMCL 1 ppm2025 Source
Sodium32.3 ppmHighest reported resultIndividual range: 7.4–32.3 ppmSource standard 160 ppm2023 Source
Lead · household tapsND ppb90th percentile · JuneAction level 15 ppb2023 Source
Copper · household taps0.975 ppm90th percentile · JuneAction level 1.3 ppm2023 Source
02Tampa Bay Water · RSWTPEFF supply sampling pointReported results, sample dates and source links5
Tampa Bay Water · RSWTPEFF supply sampling point
Substance / indicatorReported resultBenchmark in sourceSample year / source
PFBAMRL is a reporting threshold, not a safety limit. The source lists PFAS compliance status as N/A; this row does not assign a current violation or home concentration.6.5 pptAverage · August and NovemberIndividual range: 5.9–7.5 pptMRL 5 ppt2025 Source
PFBSMRL is a reporting threshold, not a safety limit. The source lists PFAS compliance status as N/A; this row does not assign a current violation or home concentration.7.4 pptAverage · August and NovemberIndividual range: 5.6–8.9 pptMRL 3 ppt2025 Source
PFHxAMRL is a reporting threshold, not a safety limit. The source lists PFAS compliance status as N/A; this row does not assign a current violation or home concentration.5.9 pptAverage · August and NovemberIndividual range: 5.4–6.4 pptMRL 3 ppt2025 Source
PFOSMRL is a reporting threshold, not a safety limit. The source lists PFAS compliance status as N/A; this row does not assign a current violation or home concentration.5.5 pptAverage · August and NovemberIndividual range: 5.3–5.7 pptMRL 4 ppt2025 Source
PFPeAMRL is a reporting threshold, not a safety limit. The source lists PFAS compliance status as N/A; this row does not assign a current violation or home concentration.7.9 pptAverage · August and NovemberIndividual range: 6.7–8.7 pptMRL 3 ppt2025 Source
03Tampa Bay Water · surface-water supplyReported results, sample dates and source links1
Tampa Bay Water · surface-water supply
Substance / indicatorReported resultBenchmark in sourceSample year / source
Foaming agentsThe source marks an aesthetic-standard violation. This supplier value is not a Pasco tap measurement.1.80 ppmHighest detected resultIndividual range: ND–1.80 ppmSecondary standard 0.5 ppm2025 Source
Selected provider records

A closer look at your local water

View full MyTapWater report

These results describe Pasco County Regional Public Water System (FL6511361), not every home or water system in Pasco County. Match this system to your water bill before using the results.

Source record: PCUD-PASCO COUNTY REGIONAL PWS · Selected test records: 2013-02-18 – 2024-05-13

How to read these results

Results come from different testing periods. A detection is not, by itself, a finding that water is unsafe. “Not detected” means below the test’s reporting level; it does not mean zero. Missing results mean we have not verified that data here.

PFAS monitoring6 of 29 tested PFAS compounds detected

The table shows each compound’s highest reported result and latest listed test date. Those may come from different samples. Results are in parts per trillion (ppt).

PFAS monitoring · Pasco County Regional Public Water System
SubstanceHighest reported resultLatest listed testDetected samples
PFOS8.1 ppt6
PFPeA10 ppt13
PFBS8.7 ppt8
PFHxA8.1 ppt11
PFBA6.7 ppt3
PFHpA3.8 ppt2
Lead and copper monitoring

These are the latest dated lead or copper records retrieved for this system. Sampling periods are shown exactly as the source lists them. Utility sampling does not measure the water at your own tap.

Lead and copper monitoring · Pasco County Regional Public Water System
SubstanceReported resultSampling periodResult type
Lead1 ppb – 90th percentile

A reported zero is reproduced as recorded; it is not reclassified as “not detected.”

Lithium monitoringNot detected

MyTapWater reports lithium was tested and not detected. Sample dates and reporting limits: see the source report.

More tested substances3 selected entries

Selected historical tests, with their original dates. “Detected” means at least one positive result in the listed period. “Below reporting level” means all retrieved samples for that entry were below the reporting level. These older tests do not describe today’s water at your tap.

More tested substances · Pasco County Regional Public Water System
SubstanceReported resultSampling period
chlorateDetected –
1,4-dioxaneDetected –
chloromethaneBelow reporting level –

This is a selection of results from MyTapWater, which compiles public water-system records. Open the source for the complete tables, methods and reporting limits. Check your utility’s latest report and current notices for updates. Source

A list of tested substances is not a list of what a filter removes. Choose a system using its verified contaminant-reduction specifications and your water source. A softener addresses hardness and remains optional.

HARD WATER, EXPLAINED

Do you need a water softener?

No. Softening is optional and is a separate decision from filtration. Use a home hardness test and your preferences about scale and water feel; your plumber confirms equipment size and settings.

A finished-water hardness range was not verified in the Pasco Regional 2025 report or county report directory reviewed here. This does not mean the water is soft. Regional estimates, chloramine levels and other contaminant results cannot replace a home hardness test. Softening remains optional. Source

Hardness describes dissolved minerals, not an overall water safety score. A filter and a softener do different jobs. Source

Use my water and home details
YOUR HOME’S HARDNESS

Test at home

No verified finished-water range is shown for this system. A home test provides a starting point.

Softening is an optional choice for scale and water feel.

START WITH THE PROBLEM

A filter, a softener, or both?

Choose the job you need done. Size comes next, based on water use and peak flow.

Whole-home filter
For filtration goals

Whole-home filter

For whole-home filtration goals. Match the exact system’s performance claims to the substances you want to address.

A filter alone does not replace a hardness-removing softener.

From$1,999.00equipment only
View system
Whole-home softener
For confirmed hard water

Whole-home softener

Optional for hard-water scale and water feel. A softener removes hardness minerals; it is not a general contaminant-removal system.

A softener does not replace a filter selected for a specific contaminant.

From$1,799.00equipment only
View system
Filter + softener
For both goals

Filter + softener

Choose both when filtration and hardness are separate priorities. You can start with the filter in the home-matching flow.

Both units require maintenance, space and a suitable installation.

From$2,999.00equipment only
View system

Proposed pricing. Installation, shipping and tax are additional. Purchases are paused during the pilot. You hire and pay your plumber directly.

When a whole-house system may be the wrong fit

For drinking water alone, a suitable kitchen-tap filter may be enough. Keep working equipment that already meets your goal. Wells, shared plumbing and unusually high demand need a separate assessment. No Clearhouse system is claimed to remove every substance in this report. Source

Choose equipment using model-specific performance evidence and maintain it as instructed. Removing disinfectant throughout a home also changes microbial protection in the plumbing. Source

MAKE IT SPECIFIC TO YOUR HOME

Your water report is the start. Your home decides the fit.

A few household details help narrow the size. Your street address is optional, and “I’m not sure” is always an option.

  1. Confirm the name on your water bill.
  2. Share bathrooms, household size and existing equipment.
  3. Choose a system. Hire your own plumber.
Start my home match

Want help choosing?

Send your water goals to Clearhouse for a fit review.

No purchase or installation booking is made by submitting this form.

Privacy policy

BEFORE YOU CHOOSE

Common questions

Why do some Pasco results say 2023 in a 2025 report?

Utilities do not sample every substance at the same frequency. The 2025 Regional report includes older permitted sampling results, including 2023 lead, copper and several inorganic results. Each row preserves its sample year. Source

Is a water softener required?

No. Softening is optional and is a separate decision from filtration. Use a home hardness test and your preferences about scale and water feel; your plumber confirms equipment size and settings.

Does this report test my home?

No. Utility reports describe particular systems and sample periods. Plumbing, service lines and treatment already in a home can change the result at the tap.

Will one whole-home filter remove everything listed?

No. Select equipment by its specific tested or certified reduction claims and rated flow. A long contaminant list is not evidence that a particular system removes every item.

TRANSPARENCY FIRST

Sources & methodology

We transcribe selected utility results and retain sample dates, units, sampling basis and source links. We separate regional supply samples from local distribution data and flag source inconsistencies. Missing data are not treated as non-detections.

Clearhouse sells water treatment equipment and is not a utility or testing laboratory. Report presence alone does not establish a health risk, a need for treatment or a product’s removal performance.

  1. Pasco Regional · 2025 · PWS 651-1361
  2. All Pasco County system reports
  3. Source · USGS
  4. Source · CDC
  5. MyTapWater · Pasco County Regional Public Water System · FL6511361 · Source reviewed October 3, 2026